Quantitative Assessment and Repeatability of Chlorine in Exhaled Breath Condensate
- 16 September 2005
- journal article
- research article
- Published by S. Karger AG in Respiration
- Vol. 72 (5) , 529-536
- https://doi.org/10.1159/000087679
Abstract
Background: Airway condition is presumably reflected in epithelial lining fluid (ELF). Exhaled breath condensate (EBC) has been used as a surrogate marker of the composition of ELF. Objectives: This study aimed at assessing the technical repeatability of chlorine measurements in EBC and comparing two separate condensators (Ecoscreen® and R Tube™) regarding recovery and repeatability. Furthermore, the association between condensate recoveries and variations in the airway status were scrutinized. Methods: EBC was collected using two condensators from 10 healthy volunteers. In addition, 13 asthmatic patients produced EBC with or without an added resistance of 5 cm H2O (Res5), applied to the outflow tract of Ecoscreen. All tests were done in random order. Chlorine levels (analyzed by a coulometric technique) in EBC served as a tool for investigation. Results: Chlorine was measurable in all samples. The coefficient of repeatability of chlorine measurements was <10%. Chlorine levels were higher in EBC obtained from R Tube (p < 0.001), and differences in recoveries and variability in chlorine levels were presumably related to technical differences in the condensators and not to the repeatability of chlorine measurements per se. Air-flow-dependent chlorine levels were obtained from healthy volunteers. Application of Res5, recruiting additional alveoli, resulted in increased recovery of the EBC volume, but not of chlorine, from those that had the most pronounced airway obstruction (p = 0.05). Conclusion: We conclude that by employing a sensitive analysis technique, chlorine is repeatedly measurable in EBC. We suggest that the bulk of chlorine in EBC originates from large airways and not from the alveolar area. Both condensators were comparable regarding repeatability but differed regarding chlorine recovery.Keywords
This publication has 17 references indexed in Scilit:
- Reduced pH and chloride levels in exhaled breath condensate of patients with chronic coughThorax, 2004
- Repeatability of sodium and chloride in exhaled breath condensatesPediatric Pulmonology, 2004
- Markers of Inflammation in Exhaled Breath Condensate of Young Healthy SmokersChest, 2004
- A Simple Method for Estimating Respiratory Solute Dilution in Exhaled Breath CondensatesAmerican Journal of Respiratory and Critical Care Medicine, 2003
- Quantitative analysis of 8‐isoprostane and hydrogen peroxide in exhaled breath condensate: Table 1—European Respiratory Journal, 2003
- Dilution of Respiratory Solutes in Exhaled CondensatesAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Collection and Analysis of Exhaled Breath Condensate in HumansAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Elemental Composition of Human Airway Surface Fluid in Healthy and Diseased AirwaysAmerican Review of Respiratory Disease, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Reference Values for Lung Function Tests in Men: Regression Equations with Smoking VariablesUpsala Journal of Medical Sciences, 1986