Particle Bounce in a Personal Cascade Impactor: A Field Evaluation
- 1 September 1985
- journal article
- research article
- Published by Taylor & Francis in Aihaj Journal
- Vol. 46 (9) , 517-523
- https://doi.org/10.1202/0002-8894(1985)046<0517:pbiapc>2.3.co;2
Abstract
The collection characteristics of five types of substrates (collection surfaces) used in personal cascade impactors were evaluated for particle bounce in the laboratory with lead dioxide dust, and in the field with brass pouring fume and brass grinding dust. The substrates tested were uncoated stainless steel, silicon grease-coated stainless steel, oil-saturated Millipore membrane filter, oil-saturated Teflon membrane filter and oil-saturated sintered stainless steel. The use of coated and uncoated stainless steel plates to collect lead dioxide dust produced no difference in measured mass median diameter (MMD); however, with brass grinding dust, there was a 50% decrease in measured MMD when uncoated stainless steel substrates were used, as compared with coated stainless steel substrates. Oil-saturated Millipore membrane surfaces gave consistently lower MMDs than coated stainless steel surfaces. Coated and uncoated stainless steel gave similar MMDs when used to sample brass pouring fume. Oil-saturated Tefl...This publication has 2 references indexed in Scilit:
- Non-ideal collection characteristics of inertial impactors—II. Cascade impactorsJournal of Aerosol Science, 1978
- Non-ideal collection characteristics of inertial impactors—I. Single-stage impactors and solid particlesJournal of Aerosol Science, 1978