Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry
Top Cited Papers
- 6 July 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 122 (1) , 62-69
- https://doi.org/10.1161/circulationaha.109.907402
Abstract
Background— Transcatheter aortic valve implantation was developed to mitigate the mortality and morbidity associated with high-risk traditional aortic valve replacement. The Edwards SAPIEN valve was approved for transcatheter aortic valve implantation transfemoral delivery in the European Union in November 2007 and for transapical delivery in January 2008. Methods and Results— The SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry was designed to assess the initial clinical results of the Edwards SAPIEN valve in consecutive patients in Europe after commercialization. Cohort 1 consists of 1038 patients enrolled at 32 centers. Patients who were treated with the transapical approach (n=575) suffered more comorbidities than the transfemoral patients (n=463), resulting in a significantly higher logistic EuroSCORE (29.1% versus 25.7%; P Conclusion— Technical proficiency can be learned and adapted readily as demonstrated by the short-term procedural success rate and low 30-day mortality rates reported in the SOURCE Registry. Specific complication management and refinement of patient selection are needed to further improve outcomes.Keywords
This publication has 19 references indexed in Scilit:
- The European System for Cardiac Operative Risk Evaluation (EuroSCORE) is not appropriate for withholding surgery in high-risk patients with aortic stenosis: a retrospective cohort studyJournal of Cardiothoracic Surgery, 2009
- Frailty after aortic valve replacement (AVR) in octogenariansArchives of Gerontology and Geriatrics, 2009
- Transcatheter aortic valve implantation (TAVI): how to interpret the data and what data is required?EuroIntervention, 2009
- Early Conduction Disorders Following Percutaneous Aortic Valve ReplacementPacing and Clinical Electrophysiology, 2009
- Progress and Current Status of Percutaneous Aortic Valve Replacement: Results of Three Device Generations of the CoreValve Revalving SystemCirculation: Cardiovascular Interventions, 2008
- Overestimation of aortic valve replacement risk by EuroSCORE: implications for percutaneous valve replacementEuropean Heart Journal, 2008
- Transapical minimally invasive aortic valve implantation; the initial 50 patients☆European Journal of Cardio-Thoracic Surgery, 2008
- High-Risk Aortic Valve Replacement: Are the Outcomes as Bad as Predicted?The Annals of Thoracic Surgery, 2008
- Percutaneous Aortic Valve Implantation Retrograde From the Femoral ArteryCirculation, 2006
- Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic StenosisCirculation, 2002