Isolation and Detection of Enterovirus RNA from Large-Volume Water Samples by Using the NucliSens miniMAG System and Real-Time Nucleic Acid Sequence-Based Amplification
Open Access
- 1 July 2005
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 71 (7) , 3734-3740
- https://doi.org/10.1128/aem.71.7.3734-3740.2005
Abstract
Concentration of water samples is a prerequisite for the detection of the low virus levels that are present in water and may present a public health hazard. The aim of this study was to develop a rapid, standardized molecular method for the detection of enteroviruses in large-volume surface water samples, using a concentration method suitable for the detection of infectious viruses as well as virus RNA. Concentration of water was achieved by a conventional filter adsorption-elution method and ultrafiltration, resulting in a 10,000-fold concentration of the sample. Isolation of virus RNA by a silica-based RNA extraction method was compared with the nonmagnetic and magnetic NucliSens RNA isolation methods. By using the silica-based RNA extraction method in two out of five samples, enterovirus RNA was detected, whereas four out of five samples were positive following RNA isolation with magnetic silica beads. Moreover, estimated RNA levels increased at least 100 to 500 times. Furthermore, we compared enterovirus detection by an in-house reverse transcription (RT)-PCR with a novel commercially available real-time nucleic acid sequence-based amplification (NASBA) assay. We found that the rapid real-time NASBA assay was slightly less sensitive than our in-house RT-PCR. The advantages, however, of a commercial real-time NASBA assay, like the presence of an internal control RNA, standardization, and enormous decrease in turnaround time, makes it an attractive alternative to RT-PCR.Keywords
This publication has 44 references indexed in Scilit:
- Presence of Noroviruses and Other Enteric Viruses in Sewage and Surface Waters in The NetherlandsApplied and Environmental Microbiology, 2005
- Characterization of a Highly Evolved Vaccine-Derived Poliovirus Type 3 Isolated from Sewage in EstoniaJournal of Virology, 2004
- Real-time PCR for rapid diagnosis of entero- and rhinovirus infections using LightCyclerJournal of Clinical Virology, 2004
- Detection of somatic phages, infectious enteroviruses and enterovirus genomes as indicators of human enteric viral pollution in surface waterWater Research, 2003
- Development and evaluation of NucliSens® Basic Kit NASBA for diagnosis of parainfluenza virus infection with ‘end-point’ and ‘real-time’ detectionJournal of Virological Methods, 2003
- Rapid Enterovirus RNA Detection in Clinical Specimens by Using Nucleic Acid Sequence-Based AmplificationJournal of Clinical Microbiology, 2003
- Rapid and Sensitive Routine Detection of All Members of the Genus Enterovirus in Different Clinical Specimens by Real-Time PCRJournal of Clinical Microbiology, 2002
- Detection, quantitation and identification of enteroviruses from surface waters and sponge tissue from the Florida Keys using real-time RT–PCRWater Research, 2002
- Detection of Hepatitis A Virus by the Nucleic Acid Sequence-Based Amplification Technique and Comparison with Reverse Transcription-PCRApplied and Environmental Microbiology, 2001
- Nucleic acid sequence-based amplificationNature, 1991