Gadolinium-enhanced three-dimensional MR angiography of the aorta and peripheral arteries: evaluation of a multistation examination using two gadopentetate dimeglumine infusions.
- 1 September 1998
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 171 (3) , 599-604
- https://doi.org/10.2214/ajr.171.3.9725281
Abstract
Three-dimensional gadolinium-enhanced MR angiography is a rapid and accurate method that can at times image only a limited amount of anatomy during an examination. We evaluated a technique that doubled the anatomy imaged by obtaining two separate gadolinium-enhanced MR angiograms during a single examination. Twenty-three patients referred for MR evaluation of aortic or peripheral vascular disease underwent two successive gadolinium-enhanced three-dimensional MR angiographic examinations during a single MR examination. An injection of 15 ml of gadopentetate dimeglumine was used for the first MR angiogram, and 25 ml was used for the second MR angiogram. The angiograms were quantitatively and qualitatively evaluated to determine the effect of residual gadolinium from the initial MR angiogram on the second angiogram. The two studies depicted either the entire aorta to the femoral arteries (n = 10) or the distal aorta to the popliteal arteries (n = 13). The total mean gadolinium dose was 0.245 mmol/kg per patient. An average of 15 min elapsed between injections. The value of arterial signal-to-noise ratio (mean, 48.8 versus 56.4) and artery-to-vein contrast-to-noise ratio (mean, 45.5 versus 49.0) increased between the first and second angiograms, respectively. Residual gadolinium elevated the values for venous signal-to-noise ratio (mean, 2.3 versus 7.2) and background-to-muscle signal-to-noise ratio (mean, 5.5 versus 10.1) on the second MR angiogram. Qualitative evaluation by three observers showed no significant differences in diagnostic usefulness or overall image quality between the first and second MR angiograms. The use of two low-dose gadolinium-enhanced three-dimensional MR angiograms during a single examination is a feasible approach to increase anatomic coverage when performing gadolinium-enhanced three-dimensional MR angiography of the aorta and peripheral vessels. Although background enhancement is slightly elevated on the second angiogram, such enhancement does not significantly change diagnostic usefulness or overall image quality.Keywords
This publication has 16 references indexed in Scilit:
- Iliac artery stenosis measurements: comparison of two-dimensional time-of-flight and three-dimensional dynamic gadolinium-enhanced MR angiography.American Journal of Roentgenology, 1997
- Gadolinium-enhanced body MR venography with subtraction technique.American Journal of Roentgenology, 1997
- Evaluation of the aortoiliac and renal arteries: comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography.Radiology, 1997
- Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography.Radiology, 1997
- Contrast-enhanced abdominal MR angiography: optimization of imaging delay time by automating the detection of contrast material arrival in the aorta.Radiology, 1997
- Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the renovascular system.American Journal of Roentgenology, 1997
- Thoracic aorta: comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging.Radiology, 1997
- Gadolinium-enhanced three-dimensional MR angiography of the thoracoabdominal aortaSeminars in Ultrasound, CT and MRI, 1996
- Gadolinium-enhanced magnetic resonance angiography of abdominal aortic aneurysmsJournal of Vascular Surgery, 1995
- Dynamic gadolinium‐enhanced three‐dimensional abdominal MR arteriographyJournal of Magnetic Resonance Imaging, 1993