Inter-element fractionation and correction in laser ablation inductively coupled plasma mass spectrometry
- 1 January 1999
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 14 (12) , 1823-1828
- https://doi.org/10.1039/a903272j
Abstract
Inter-element fractionation in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) analysis is one of the major challenges for using the technique for in situ trace element determination and isotopic ratio measurement of geological, environmental and biological solid samples. Attempts have been made to reduce inter-element fractionation in LA-ICP-MS analysis. However, this fractionation cannot be eliminated. The mechanism of the fractionation in LA-ICP-MS analysis is not very well understood. This study investigated the inter-element fractionation of seven elements (Ca, V, Zn, Ga, Sr, La and Nd) in three different sample matrices (NIST 613, BCR-2 and SY-4) using a UV 266 nm laser. The study showed that the inter-element fractionation depends on the sample matrices and varies with time. The inter-element fractionation behaviour of V, Zn and Ga in the synthetic silicate glass NIST 613 is different from that in the quenched glass of fused silicate rocks (BCR-2 and SY-4). Relative to Ca, V, Zn and Ga show less fractionation in NIST 613 but larger fractionation in BCR-2 and SY-4. The relative internal standard normalized element intensity (RISNEI) is not linear with time for a laser ablation period of 210 s. Therefore, data acquisition using prolonged laser ablation without a matrix match will not improve the precision and accuracy for elements whose fractionation behavior is different from that of the internal standard element. The RISNEI versus time relationship for the first 100 s laser ablation can be treated as linear to simplify the data calculation. In this paper, the internal standard normalized fractionation factor (ISNFF) is defined as the sum of the second half average RISNEI and the difference between the second and first half average RISNEI, divided by the second half RISNEI of data acquisition, for the analyte concentration calculation. The ISNFF was applied for the correction of the data reduction in LA-ICP-MS analysis. The data accuracy for these seven elements is generally improved, particularly for an element whose calibration standard normalized ISNFF is significantly greater or less than 1 (e.g., Zn and Ga in this study). Good accuracy can be obtained for elements without ISNFF correction and matrix matches only if the calibration standard normalized ISNFF of the elements is close to 1.Keywords
This publication has 15 references indexed in Scilit:
- Application of a frequency quintupled Nd:YAG source (λ=213 nm) for laser ablation inductively coupled plasma mass spectrometric analysis of mineralsJournal of Analytical Atomic Spectrometry, 1998
- Rapid and simultaneous multi-element analysis of atmospheric particulate matter using inductively coupled plasma mass spectrometry with laser ablation sample introductionJournal of Analytical Atomic Spectrometry, 1998
- Ablative and transport fractionation of trace elements during laser sampling of glass and copperSpectrochimica Acta Part B: Atomic Spectroscopy, 1997
- Quantitative Analysis for Impurities in Uranium by Laser Ablation Inductively Coupled Plasma Mass Spectrometry: Improvements in the Experimental SetupJournal of Analytical Atomic Spectrometry, 1997
- Application of Laser Sampling Microprobe Inductively Coupled Plasma Mass Spectrometry to theIn Situ Trace Element Analysis of Selected Geological MaterialsJournal of Analytical Atomic Spectrometry, 1997
- Chemical fractionation during infrared and ultraviolet laser ablation inductively coupled plasma mass spectrometry—implications for mineral microanalysisAnalytical Communications, 1996
- CANADIAN DIORITE GNEISS SY‐4: PREPARATION AND CERTIFICATION BY EIGHTY‐NINE INTERNATIONAL LABORATORIESGeostandards Newsletter, 1995
- Non-destructive sampling method of metals and alloys for laser ablation-inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1995
- Applications of laser ablation inductively coupled plasma mass spectrometry to the determination of environmental contaminants in calcified biological structuresJournal of Analytical Atomic Spectrometry, 1994
- The application of laser ablation microprobe-inductively coupled plasma-mass spectrometry (LAM-ICP-MS) to in situ (U)Pb geochronologyChemical Geology, 1993