Comparison of intraabdominal pressures using the gastroscope and laparoscope for transgastric surgery
- 3 April 2007
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (6) , 998-1001
- https://doi.org/10.1007/s00464-006-9167-7
Abstract
The peroral transgastric endoscopic approach for intraabdominal procedures appears to be feasible, although multiple aspects of this approach remain unclear. This study aimed to measure intraperitoneal pressure in a porcine model during the peroral transgastric endoscopic approach, comparing an endoscopic on-demand insufflator/light source with a standard autoregulated laparoscopic insufflator. All experiments were performed with 50-kg female pigs under general anesthesia. A standard upper endoscope was advanced perorally through a gastric wall incision into the peritoneal cavity. The peritoneal cavity was insufflated with operating room air from an endoscopic light source/insufflator. Intraperitoneal pressure was measured by three routes: (1) through the endoscope biopsy channel, (2) through a 5-mm transabdominal laparoscopic port, and (3) through a 16-gauge Veress needle inserted into the peritoneal cavity through the anterior abdominal wall. The source of insufflation alternated between on-demand manual insufflation through the endoscopic light source/insufflator using room air and a standard autoregulated laparoscopic insufflator using carbon dioxide (CO2). Six acute experiments were performed. Intraperitoneal pressure measurements showed good correlation regardless of measurement route and were independent of the type of insufflation gas, whether room air or CO2. On-demand insufflation with the endoscopic light source/insufflator resulted in a wide variation in pressures (range, 4–32 mmHg; mean, 16.0 ± 11.7). Intraabdominal pressures using a standard autoregulated laparoscopic insufflator demonstrated minimal fluctuation (range, 8–15 mmHg; mean, 11.0 ± 2.2 mmHg) around a predetermined value. Use of an on-demand unregulated endoscopic light source/insufflator for translumenal surgery can cause large variation in intraperitoneal pressures and intraabdominal hypertension, leading to the risk of hemodynamic and respiratory compromise. Safety may favor well-controlled intraabdominal pressures achieved with a standard autoregulated laparoscopic insufflator.Keywords
This publication has 18 references indexed in Scilit:
- Survival studies after endoscopic transgastric oophorectomy and tubectomy in a porcine modelGastrointestinal Endoscopy, 2006
- Transgastric anastomosis by using flexible endoscopy in a porcine model (with video)Gastrointestinal Endoscopy, 2006
- Laparoscopic ventral hernia repair without sutures--double crown technique: our experience after 140 cases with a mean follow-up of 40 months.2006
- Transgastric endoscopic splenectomySurgical Endoscopy, 2006
- ASGE/SAGES Working Group on Natural Orifice Translumenal Endoscopic SurgerySurgical Endoscopy, 2006
- Comparison of carbon dioxide and room air pneumoperitoneum for day-case diagnostic laparoscopyJournal of Obstetrics and Gynaecology, 2005
- CO2 Pneumoperitoneum Modifies the Inflammatory Response to SepsisAnnals of Surgery, 2003
- Comparative analysis of laparoscopic versus open splenectomyThe American Journal of Surgery, 1996
- Haemodynamic effects of pneumoperitoneum and the influence of posture during anaesthesia for laparoscopic surgeryActa Anaesthesiologica Scandinavica, 1994
- Hemodynamic Changes During Laparoscopic CholecystectomyAnesthesia & Analgesia, 1993