Evaluation of a new generation of plastic culture bottles with an automated microbial detection system for nine common contaminating organisms found in PLT components
- 11 March 2004
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 44 (3) , 359-363
- https://doi.org/10.1111/j.1537-2995.2003.00617.x
Abstract
BACKGROUND: A microbial detection system (BacT/ALERT 3D, bioMérieux [formerly Organon Teknika]) has previously been validated with a variety of bacterial contaminants in PLTs. The recovery of nine organisms seeded into PLTs with new plastic culture bottles was studied in comparison to the current glass bottles. The use of plastic instead of glass would be expected to reduce the risk of injury.STUDY DESIGN AND METHODS: Isolates of Bacillus cereus, Enterobacter cloacae, Escherichia coli, Klebsiella pneumoniae, Staphylococcus aureus, Staphylococcus epidermidis, Serratia marcescens, Streptococcus viridans, and Propionibacterium acnes were inoculated into Day 2 (>24 hr RESULTS: All organisms (with the exception of P. acnes) were detected in a mean time of 9.3 to 18.9 hours (10 CFUs/mL) or 8.7 to 18.2 hours (100 CFUs/mL). In aggregate (with the exception of P. acnes), the plastic and glass aerobic bottles had a mean difference in detection of 1.2 hours (p < 0.0001), and the plastic and glass anaerobic bottles had a mean difference of 3.3 hours (p < 0.0001). In all cases, the mean detection time was superior or clinically comparable (within 0.1 hr) with the new plastic bottles. P. acnes (an anaerobic organism) was detected with the new and current anaerobic bottles in a mean of 72.8 and 90.4 hours (10 CFUs/mL) or 64.0 and 80.8 hours (100 CFUs/mL), respectively. The narrower bottle neck and smaller inoculation septum present with the new‐generation plastic bottles were inoculated with comparable ease to that of the glass bottles.CONCLUSIONS: These data demonstrate that the new plastic bottles are clinically comparable or superior to the current glass standard aerobic and anaerobic culture bottles.Keywords
This publication has 16 references indexed in Scilit:
- Transfusion medicine: looking to the futurePublished by Elsevier ,2003
- Evaluation of an automated culture systemfor detecting bacterial contamination of platelets: an analysis with 15 contaminating organismsTransfusion, 2001
- A retrospective analysis of microbial contaminants in outdated random‐donor platelets from multiple sitesTransfusion, 1997
- Allogeneic blood transfusions, immunomodulation, and postoperative bacterial infection: Do we have the answers yet?Transfusion, 1997
- The use of a chemiluminescence‐linked universal bacterial ribosomal RNA gene probe and blood gas analysis for the rapid detection of bacterial contamination in white cell‐reduced and nonreduced plateletsTransfusion, 1993
- Bacterial proliferation in platelet concentratesTransfusion, 1986
- Escherichia coli sepsis from contaminated platelet transfusionArchives of internal medicine (1960), 1986
- Bacteriocidal Properties of Platelet ConcentratesTransfusion, 1974
- Detection and Quantitation of Bacteria in Platelet Products Stored at Ambient TemperatureTransfusion, 1973
- Bacterial contamination of platelet concentrates stored at 20°CJournal of Clinical Pathology, 1973