Reducing vascular access morbidity: a comparative trial of two vascular access monitoring strategies.
Open Access
- 1 June 2003
- journal article
- research article
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 18 (6) , 1174-1180
- https://doi.org/10.1093/ndt/gfg122
Abstract
Background. Thrombosis is the primary cause of access failure in polytetrafluoroethylene grafts and arteriovenous fistulas. It can lead to significant patient and access morbidity and mortality, and is difficult to prevent medically. Intervention is largely limited to maximizing access patency by detecting culprit lesions early and intervening with angioplasty or surgical revision. The most efficacious monitoring strategy is undetermined. Methods. This 3 year prospective study took advantage of a change in monitoring strategy used in a large dialysis centre to compare the efficacy of two methods used to monitor grafts and fistulas in order to prevent access thrombosis. Accesses were monitored using Duplex ultrasonography in year 1, while the saline ultrasound dilution technique (Transonic) became the primary monitoring strategy in year 3 (year 2 was a transition year). Risk factors for thrombosis were determined using multivariate survival analysis, and the performance of Duplex ultrasonography and Transonic monitoring was assessed. Results. A total of 303 656 access days at risk were assessed, with 344, 385 and 425 accesses in years 1, 2 and 3, respectively. The total thrombosis rate was 1.01/1000 access days in year 1 compared with 0.66/1000 access days in year 3. This was accomplished despite a reduction in procedure rates of 55% for angiograms, 13% for angioplasties and 31% for thrombolysis. Conclusion. Low flow rates detected using Transonic monitoring were associated with increased thrombosis, while stenosis detected using Duplex ultrasonography was not a strong predictor of incipient thrombosis; however, these different access characteristics were compared using monitoring techniques that may be ideal in different clinical situations.Keywords
This publication has 15 references indexed in Scilit:
- Hemodialysis arteriovenous access: Detection of stenosis and response to treatment by vascular access blood flowKidney International, 2001
- A practical approach to vascular access for hemodialysis and predictors of successJournal of Vascular Surgery, 1999
- Vascular access for hemodialysisKidney International, 1999
- Predictive measures of vascular access thrombosis: A prospective studyKidney International, 1997
- Prophylactic balloon angioplasty fails to prolong the patency of expanded polytetrafluoroethylene arteriovenous grafts: Results of a prospective randomized studyJournal of Vascular Surgery, 1997
- The relationship of recirculation to access blood flowAmerican Journal of Kidney Diseases, 1997
- Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosisKidney International, 1995
- Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts.RadioGraphics, 1993
- The Effect of Doppler Flow Screening Studies and Elective Revisions on Dialysis Access FailureAsaio Journal, 1992
- Prevention of hemodialysis fistula thrombosis. Early detection of venous stenosesKidney International, 1989