The Detection and Potential Economic Value of Complexed Prostate Specific Antigen as a First Line Test
- 1 March 2006
- journal article
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 175 (3) , 897-901
- https://doi.org/10.1016/s0022-5347(05)00343-5
Abstract
Prostate cancer detection is subject to a number of variables that can lead to unnecessary biopsies and associated costs. Measuring cPSA has been proposed as an alternative to tPSA for the early detection of prostate cancer. Between November 1998 and April 2000, 1,362 men underwent transrectal ultrasound guided biopsies at 7 institutions. Of 1,243 evaluable men 467 with tPSA between 2.5 and 6.0 ng/ml, and normal digital rectal examination were analyzed. Statistical analysis used to compare cancer detection rates between PSA assays was performed using the Mann-Whitney U test. A separate group of 2,807 men who participated in a free cancer detection program was used to determine the current tPSA distribution and assess the economic impact of cPSA. Cancer was detected in 31.5% of the men (147 of 467) with tPSA between 2.5 and 6.0 ng/ml. Using a 2.2 ng/ml cPSA cutoff point detected 93.9% of cancers and would have avoided 20.3% of unnecessary biopsies in men with tPSA between 2.5 and 4.0 ng/ml. A 2.2 ng/ml cPSA cutoff point achieved an 11.9% overall decrease in the number of unnecessary biopsies in the tPSA range of 2.5 to 6.0 ng/ml with accompanying 98% sensitivity. The decrease in unnecessary biopsies is potentially associated with substantial health care cost savings. In the clinically relevant sensitivity ranges a 2.2 ng/ml cPSA cutoff point decreases the number of unnecessary biopsies and maintains higher specificity than a tPSA threshold of 2.5 ng/ml, illustrating the potential value of cPSA as a first line diagnostic test.Keywords
This publication has 16 references indexed in Scilit:
- THE PROSTATE SPECIFIC ANTIGEN ERA IN THE UNITED STATES IS OVER FOR PROSTATE CANCER: WHAT HAPPENED IN THE LAST 20 YEARS?Journal of Urology, 2004
- Complexed prostate specific antigen (PSA) reduces unnecessary prostate biopsies in the 2.6–4.0 ng/mL range of total PSABJU International, 2004
- Complexed Prostate Specific Antigen Improves Specificity for Prostate Cancer Detection: Results of a Prospective Multicenter Clinical TrialJournal of Urology, 2003
- Effect of Verification Bias on Screening for Prostate Cancer by Measurement of Prostate-Specific AntigenNew England Journal of Medicine, 2003
- Complexed prostate-specific antigen, complexed prostate-specific antigen density of total and transition zone, complexed/total prostate-specific antigen ratio, free-to-total prostate-specific antigen ratio, density of total and transition zone prostate-specific antigen: results of the prospective multicenter European trialUrology, 2002
- Complexed prostate-specific antigen for early detection of prostate cancer in men with serum prostate-specific antigen levels of 2 to 4 nanograms per milliliterUrology, 2002
- Can volume measurement of the prostate enhance the performance of complexed prostate-specific antigen?Urology, 2002
- Prostate-specific antigen testing in black and white men: an analysis of medicare claims from 1991–1998Urology, 2002
- Prostate cancer detection in men with serum PSA concentrations of 2.6 to 4.0 ng/mL and benign prostate examination. Enhancement of specificity with free PSA measurementsJAMA, 1997
- Measurement of Prostate-Specific Antigen in Serum as a Screening Test for Prostate CancerNew England Journal of Medicine, 1991