Application of a circulating-cathodic-antigen (CCA) strip test and real-time PCR, in comparison with microscopy, for the detection ofSchistosoma haematobiumin urine samples from Ghana
Top Cited Papers
- 1 October 2008
- journal article
- research article
- Published by Taylor & Francis in Pathogens and Global Health
- Vol. 102 (7) , 625-633
- https://doi.org/10.1179/136485908x337490
Abstract
In the detection of parasitic infection, the traditional methods based on microscopy often have low sensitivity and/or specificity compared with the newer, molecular tests. An assay based on real-time PCR and a reagent strip test for detecting circulating cathodic antigen (CCA) have both now been compared with urine filtration and microscopy, in the detection of Schistosoma haematobium infections. Urine samples, obtained from 74 'cases' in areas of Ghana with endemic S. haematobium and 79 'controls' from non-endemic areas, were each checked using the three methods. With the results of the filtration and microscopy taken as the 'gold standard', real-time PCR was found to be 100% specific and 89% sensitive whereas the CCA strips were 91% specific and 41% sensitive. With the samples found to contain ≥50 eggs/10 ml (indicating relatively intense infections), the sensitivities of the PCR and CCA were higher, at 100% and 62%, respectively. As expected, egg counts were negatively correlated with the number of amplification cycles needed, in the PCR, to give a signal that exceeded the background (r=−0.38; PS. haematobium infections. The PCR has optimal specificity and high sensitivity but the specificity of the CCA strips and the sensitivity of both tools could still be improved. A more thorough re-evaluation of the sensitivity and specificity of microscopy and these newer diagnostic methods, with an estimation of the cost-effectiveness of each technique, is recommended.Keywords
This publication has 21 references indexed in Scilit:
- School-based control of urinary schistosomiasis on Zanzibar, Tanzania: Monitoring micro-haematuria with reagent strips as a rapid urological assessmentJournal of Pediatric Urology, 2007
- Field-based evaluation of a reagent strip test for diagnosis of Schistosoma mansoni by detecting circulating cathodic antigen in urine before and after chemotherapyTransactions of the Royal Society of Tropical Medicine and Hygiene, 2007
- Human schistosomiasisThe Lancet, 2006
- A new PCR-based approach for the specific amplification of DNA from different Schistosoma species applicable to human urine samplesParasitology, 2006
- Applicability of a monoclonal antibody‐based dipstick in diagnosis of urinary schistosomiasis in the Central Region of GhanaTropical Medicine & International Health, 2004
- Determinants of health‐seeking behaviour for schistosomiasis‐related symptoms in the context of integrating schistosomiasis control within the regular health services in GhanaTropical Medicine & International Health, 2004
- Ill-health reported by schoolchildren during questionnaire surveys in Ghana, Mozambique and TanzaniaTropical Medicine & International Health, 2003
- Specificity of circulating antigen detection for schistosomiasis mansoni in Senegal and BurundiTropical Medicine & International Health, 2000
- Worm burdens in schistosome infectionsParasitology Today, 1996
- Diagnostic techniques in schistosomiasis control. A reviewActa Tropica, 1993