Numerical dosimetry at power-line frequencies using anatomically based models
- 1 January 1992
- journal article
- review article
- Published by Wiley in Bioelectromagnetics
- Vol. 13 (S1) , 43-60
- https://doi.org/10.1002/bem.2250130706
Abstract
We have used the finite-difference time-domain (FDTD) method to calculate induced current densities in a 1.31-cm (nominal 1/2 in) resolution anatomically based model of the human body for exposure to purely electric, purely magnetic, and combined electric and magnetic fields at 60 Hz. This model based on anatomic sectional diagrams consists of 45,024 cubic cells of dimension 1.31 cm for which the volume-averaged tissue properties are prescribed. It is recognized that the conductivities of several tissues (skeletal muscle, bone, etc.) are highly anisotropic for power-line frequencies. This has, however, been neglected in the first instance and will be included in future calculations. Because of the quasi-static nature of coupling at the power-line frequencies, a higher quasi-static frequency f' may be used for irradiation of the model, and the internal fields E' thus calculated can be scaled back to the frequency of interest, e.g., 60 Hz. Since in the FDTD method one needs to calculate in the time domain until convergence is obtained (typically 3-4 time periods), this frequency scaling to 5-10 MHz for f' reduces the needed number of iterations by over 5 orders of magnitude. The data calculated for the induced current and its variation as a function of height are in excellent agreement with the data published in the literature. The average current densities calculated for the various sections of the body for the magnetic field component (H) are considerably smaller (by a factor of 20-50) than those due to the vertically polarized electric field component when the ratio E/H is 377 ohms. We have also used the previously described impedance method to calculate the induced current densities for the anatomically based model of the human body for the various orientations of the time-varying magnetic fields, namely from side to side, front to back, or from top to bottom of the model, respectively.Keywords
This publication has 27 references indexed in Scilit:
- SAR and induced current distributions for operator exposure to RF dielectric sealersIEEE Transactions on Electromagnetic Compatibility, 1991
- Currents induced in an anatomically based model of a human for exposure to vertically polarized electromagnetic pulsesIEEE Transactions on Microwave Theory and Techniques, 1991
- RF Currents Induced in an Anatomically-based Model of a Human for Plane-wave Exposures (20-100 MHz)Health Physics, 1989
- Electromagnetic deposition in an anatomically based model of man for leakage fields of a parallel-plate dielectric heaterIEEE Transactions on Microwave Theory and Techniques, 1989
- An Impedance Method to Calculate Currents Induced in Biological Bodies Exposed to Quasi-Static Electromagnetic FieldsIEEE Transactions on Electromagnetic Compatibility, 1985
- Impedence Method for Calculation of Power Deposition Patterns in Magnetically Induced HyperthermiaIEEE Transactions on Biomedical Engineering, 1984
- Anisotropy in the dielectric properties of skeletal muscleMedical & Biological Engineering & Computing, 1983
- State of the knowledge for electromagnetic absorbed dose in man and animalsProceedings of the IEEE, 1980
- Analysis of the Proximity Effects in Electric Field MeasurementsIEEE Transactions on Power Apparatus and Systems, 1978
- Currents induced in the human body by high voltage transmission line electric fieldߞMeasurement and calculation of distribution and doseIEEE Transactions on Power Apparatus and Systems, 1977