Comparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults
Open Access
- 1 May 1999
- journal article
- clinical trial
- Published by Elsevier in The American Journal of Clinical Nutrition
- Vol. 69 (5) , 898-903
- https://doi.org/10.1093/ajcn/69.5.898
Abstract
Background: Over the past decade, considerable attention has been paid to accurately measuring body composition in diverse populations. Recently, the use of air-displacement plethysmography (AP) was proposed as an accurate, comfortable, and accessible method of body-composition analysis. Objective: The purpose of this study was to compare measurements of percentage body fat (%BF) by AP and 2 other established techniques, hydrostatic weighing (HW) and bioelectrical impedance analysis (BIA), in adults. Design: The sample consisted of healthy men (n = 23) and women (n = 24). %BF was measured by AP, HW, and BIA. Results: In the total group, %BFAP (25.0 ± 8.9%) was not significantly different from %BFHW (25.1 ± 7.7%) or %BFBIA (23.9 ± 7.7%), and %BFAP was significantly correlated with %BFHW (r = 0.944, P < 0.001) and with %BFBIA (r = 0.859, P < 0.01). Compared with HW, AP underestimated %BF in men (by −1.24 ± 3.12%) but overestimated %BF in women (by 1.02 ± 2.48%), indicating a significant sex effect (P < 0.05). The differences in estimation between AP and BIA and between BIA and HW were not significantly different between the sexes. Conclusion: AP is an accurate method for assessing body composition in healthy adults. Future studies should assess further the cause of the individual variations with this new method.Keywords
This publication has 11 references indexed in Scilit:
- Evaluation of Body CompositionSports Medicine, 1996
- Bioelectrical impedance analysis measurements as part of a national nutrition surveyThe American Journal of Clinical Nutrition, 1996
- Validity of bioelectrical impedance equations for estimating percent fat in malesMedicine & Science in Sports & Exercise, 1996
- An evaluation of a bioelectrical impedance analyser for the estimation of body fat content.British Journal of Sports Medicine, 1993
- Validity of bioelectrical-impedance analysis in measuring changes in lean body mass during weight reductionThe American Journal of Clinical Nutrition, 1991
- Sensitivity of bioelectrical impedance to detect changes in human body compositionJournal of Applied Physiology, 1989
- Reliability and validity of bioelectrical impedance in determining body compositionJournal of Applied Physiology, 1988
- Techniques of Measurement of Body CompositionSports Medicine, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Density of lean body mass is greater in blacks than in whitesJournal of Applied Physiology, 1984