Performance characteristics of a microMOSFET as anin vivodosimeter in radiation therapy
- 20 August 2004
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (17) , 4031-4048
- https://doi.org/10.1088/0031-9155/49/17/014
Abstract
The commercially available microMOSFET dosimeter was characterized for its dosimetric properties in radiotherapy treatments. The MOSFET exhibited excellent correlation with the dose and was linear in the range of 5-500 cGy. No measurable effect in response was observed in the temperature range of 20-40 degrees C. No significant change in response was observed by changing the dose rate between 100 and 600 monitor units (MU) min(-1) or change in the dose per pulse. A 3% post-irradiation fading was observed within the first 5 h of exposure and thereafter it remained stable up to 60 h. A uniform energy response was observed in the therapy range between 4 MV and 18 MV. However, below 0.6 MeV (Cs-132), the MOSFET response increased with the decrease in energy. The MOSFET also had a uniform dose response in 6-20 MeV electron beams. The directional dependence of MOSFET was within +/-2% for all the energies studied. The inherent build-up of the MOSFET was evaluated dosimetrically and found to have varying water equivalent thickness, depending on the energy and the side of the beam entry. At depth, a single calibration factor obtained by averaging the MOSFET response over different field sizes, energies, orientation and depths reproduced the ion chamber measured dose to within 5%. The stereotactic and the penumbral measurements demonstrated that the MOSFET could be used in a high gradient field such as IMRT. The study showed that the microMOSFET dosimeter could be used as an in vivo dosimeter to verify the dose delivery to the patient to within +/-5%.Keywords
This publication has 24 references indexed in Scilit:
- CHARACTERIZATION OF THE ANGULAR RESPONSE OF AN “ISOTROPIC” MOSFET DOSIMETERHealth Physics, 2003
- Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM codeMedical Physics, 2002
- In vivo dosimetry during conformal radiotherapyRadiotherapy and Oncology, 1999
- A method to improve the effectiveness of diodein vivodosimetryMedical Physics, 1998
- Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beamsMedical Physics, 1998
- Clinical dosimetry using mosfetsInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Quantitative assessment of beam perturbations caused by silicon diodes used for in vivo dosimetryInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Fast and slow border traps in MOS devicesIEEE Transactions on Nuclear Science, 1996
- Evaluation of a dual bias dual metal oxide‐silicon semiconductor field effect transistor detector as radiation dosimeterMedical Physics, 1994
- Design of parallel plate ion chambers for buildup measurements in megavoltage photon beamsMedical Physics, 1992