Outcome of primary radiocephalic fistula for haemodialysis
Open Access
- 1 February 1999
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 86 (2) , 211-216
- https://doi.org/10.1046/j.1365-2168.1999.01007.x
Abstract
Background: Patient characteristics may help select the most appropriate type of permanent vascular access for haemodialysis. The aim of this study was to assess the influence of patient-related variables on the outcome of radiocephalic fistulas. Methods: Over 3 years 107 consecutive patients underwent formation of a radiocephalic fistula for permanent haemodialysis access. Patients receiving prosthetic, ulnar, brachial or secondary fistulas were excluded. Patients were followed prospectively until access failure, transplantation or death, or for a minimum of 6 months (median follow-up 24 months). Results: Primary patency was 69 per cent at 12 months and 56 per cent at 24 months. Endovascular and surgical intervention led to limited improvement in secondary patency to 63 per cent at 24 months. Regression analysis showed that fistula failure was more common in women (P = 0·02), diabetics (P = 0·03) and young patients (P = 0·02). By life-table analysis, primary and secondary patency were significantly better (P = 0·01) for men and non-diabetics, while the outcome was similar for all age groups. Conclusion: One-third of radiocephalic fistulas fail irreversibly within 2 years. Failure is more likely in women and diabetic patients.Keywords
This publication has 20 references indexed in Scilit:
- Hemodialysis Access Graft Stenosis: Percutaneous Transluminal AngioplastyJournal of Surgical Research, 1997
- Detection and treatment of dysfunctional hemodialysis access grafts: effect of a surveillance program on graft patency and the incidence of thrombosis.Radiology, 1996
- Have the results of infrainguinal bypass improved with the widespread utilisation of postoperative surveillance?Published by Elsevier ,1996
- Failure of Dialysis Access: Revise or Replace?Journal of Surgical Research, 1996
- Dialysis access grafts: anatomic location of venous stenosis and results of angioplasty.Radiology, 1995
- Long-Term Survival of Vascular Accesses in a Large Chronic Hemodialysis PopulationNephron, 1995
- Insufficient dialysis shunts: improved long-term patency rates with close hemodynamic monitoring, repeated percutaneous balloon angioplasty, and stent placement.Radiology, 1993
- Fistula dysfunction: Effect on rapid hemodialysisKidney International, 1992
- The correlation between clinical and Duplex ultrasound parameters and the development of complications in arterio-venous fistulae for haemodialysisEuropean Journal of Vascular Surgery, 1990
- Vascular Access for Hemodialysis Patency Rates and Results of RevisionAnnals of Surgery, 1985