Simulations to design an online motion compensation system for scanned particle beams
- 6 July 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (14) , 3517-3531
- https://doi.org/10.1088/0031-9155/51/14/016
Abstract
Respiration-induced target motion is a major problem in intensity-modulated radiation therapy. Beam segments are delivered serially to form the total dose distribution. In the presence of motion, the spatial relation between dose deposition from different segments will be lost. Usually, this results in over- and underdosage. Besides such interplay effects between target motion and dynamic beam delivery as known from photon therapy, changes in internal density have an impact on delivered dose for intensity-modulated charged particle therapy. In this study, we have analysed interplay effects between raster scanned carbon ion beams and target motion. Furthermore, the potential of an online motion strategy was assessed in several simulations. An extended version of the clinical treatment planning software was used to calculate dose distributions to moving targets with and without motion compensation. For motion compensation, each individual ion pencil beam tracked the planned target position in the lateral as well as longitudinal direction. Target translations and rotations, including changes in internal density, were simulated. Target motion simulating breathing resulted in severe degradation of delivered dose distributions. For example, for motion amplitudes of +/-15 mm, only 47% of the target volume received 80% of the planned dose. Unpredictability of resulting dose distributions was demonstrated by varying motion parameters. On the other hand, motion compensation allowed for dose distributions for moving targets comparable to those for static targets. Even limited compensation precision (standard deviation approximately 2 mm), introduced to simulate possible limitations of real-time target tracking, resulted in less than 3% loss in dose homogeneity.Keywords
This publication has 37 references indexed in Scilit:
- 3D Online compensation of target motion with scanned particle beamRadiotherapy and Oncology, 2004
- Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectorsPhysics in Medicine & Biology, 2004
- Effects of motion on the total dose distributionSeminars in Radiation Oncology, 2004
- Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulationPhysics in Medicine & Biology, 2002
- The effect of breathing and set-up errors on the cumulative dose to a lung tumorRadiotherapy and Oncology, 2001
- Calibration of three-dimensional ultrasound images for image-guided radiation therapyPhysics in Medicine & Biology, 2001
- What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?Radiotherapy and Oncology, 1998
- The university of Florida frameless high-precision stereotactic radiotherapy systemInternational Journal of Radiation Oncology*Biology*Physics, 1997
- 59 Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalationInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Magnetic scanning system for heavy ion therapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993