Direct monitoring of toxic compounds in air using a portable mass spectrometer
- 28 February 2006
- journal article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 131 (4) , 556-567
- https://doi.org/10.1039/b517541k
Abstract
A portable tandem mass spectrometer, capable of performing atmospheric pressure chemical ionization (APCI) using a direct atmospheric inlet, is applied to the real-time monitoring of toxic compounds in air. Analytes of interest include dimethyl methylphosphonate, arsine, benzene, toluene, pyridine and vinyl acetate. The detection, identification and quantification of organic and inorganic compounds in air is demonstrated using short analysis times (<5 seconds) with detection limits in the low ppb (v/v) levels and linear dynamic ranges of several orders of magnitude. Highly specific detection and identification is achieved, even when the analyte is a trace component in a complex mixture including such interferents as fuels, lubricants, and cleaners. The effects of environmental conditions, including temperature and humidity, are delineated. Receiver operating characteristic (ROC) curves are presented to show the trade-off between false positive and false negative detection rates. Tandem mass spectrometry based both on collision-induced dissociation and on selective atmospheric pressure ion/molecule reactions is also used to increase selectivity and sensitivity.Keywords
This publication has 68 references indexed in Scilit:
- Desorption electrospray ionization with a portable mass spectrometer: in situ analysis of ambient surfacesChemical Communications, 2006
- Atmospheric Pressure Ionization in a Miniature Mass SpectrometerAnalytical Chemistry, 2005
- Sensing technology for chemical-warfare agents and its evaluation using authentic agentsSensors and Actuators B: Chemical, 2005
- Miniature Cylindrical Ion Trap Mass SpectrometerAnalytical Chemistry, 2002
- Real-time quantitative analysis of H2, He, O2, and Ar by quadrupole ion trap mass spectrometryJournal of the American Society for Mass Spectrometry, 2002
- Double resonance ejection in a micro ion trap mass spectrometerRapid Communications in Mass Spectrometry, 2002
- Conventional analytical methods for chemical warfare agentsPure and Applied Chemistry, 2002
- Hand-portable gas-detector array (GDA) for rapid field detection and identification of chemical threatField Analytical Chemistry & Technology, 2000
- Electron impact ionization in a microion trap mass spectrometerReview of Scientific Instruments, 1999
- Micro ion trap mass spectrometryRapid Communications in Mass Spectrometry, 1999