Plasma Assay of Salbutamol by Means of High-Performance Liquid Chromatography with Amperometric Determination Using a Loop Column for Injection of Plasma Extracts. Application to the Evaluation of Subcutaneous Administration of Salbutamol
- 1 June 1992
- journal article
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 14 (3) , 243-248
- https://doi.org/10.1097/00007691-199206000-00011
Abstract
An isocratic high-performance liquid chromatography method with amperometric detection for the assay of plasma salbutamol is described. The plasma extract is injected into the chromatographic system via a loop column. This insures the purification of the injected extracts and allows a simple and rapid liquid-solid extraction procedure. The good reliability, as shown by the low limit of detection (0.5 ng/ml) and a precision ranging between 5 and 10%, has permitted the investigation of a new mode of administration of salbutamol using a portable subcutaneous infusion pump. Our results show that subcutaneous administration yields plasma levels comparable with those obtained after usual intravenous doses.Keywords