We have developed a reproducible model of granuloma formation in the mouse lung using a narrow size range (45–53 μm) of divinyl benzene copolymer beads as a standard test material. Approximately 10,000 beads are given by intravenous injection into the tail veins of mice whence they embolize to the lung and incite granuloma formation. This delivery system eliminates the superimposed inflammatory reaction due to trauma that occurs when materials are directly implanted at the test site by surgical incision. Granuloma size was quantitated at intervals from 3 h to 6 weeks by tracing mid‐bead granuloma areas on the ground glass screen of a light microscope at a known magnification and measuring the areas with a digitizer interfaced with a microcomputer programmed to prepare histograms and to merge data from replicate experiments. At 3 h only a few polymorphonuclear leukocytes could be observed adhering to the beads. At 48 h, the time of maximum granuloma size (mean area = 750l μm2), the granulomas consisted of both polymorphonuclear and mononuclear leukocytes. After 6 weeks, the granulomas were smaller, composed predominantly of mononuclear leukocytes and had a mean area of 2893 m̈m2. This model system allows the analysis of a large number of measurements, is reproducible, and provides a useful method for comparing the hosts' inflammatory response to a variety of potential biomaterials, as well as for determining the effectiveness of anti‐inflammatory drugs.This publication has 14 references indexed in Scilit:
- A low-viscosity epoxy resin embedding medium for electron microscopyPublished by Elsevier ,2004
- Biomaterials for drug delivery systemsJournal of Biomedical Materials Research, 1983
- Current status of biomaterials in ophthalmologySurvey of Ophthalmology, 1982
- BiomaterialsScience, 1980
- Problems and artefacts in the evaluation of polymeric materials for medical usesBiomaterials, 1980
- THE ADSORPTION AND CONFORMATION OF PLASMA PROTEINS: A PHYSICAL APPROACH*Annals of the New York Academy of Sciences, 1977
- ELLIPSOMETRIC STUDY OF PROTEIN FILM ON CHROMIUMAnnals of the New York Academy of Sciences, 1977
- Direct chemical bond of bioactive glass‐ceramic materials to bone and muscleJournal of Biomedical Materials Research, 1973
- Bonding mechanisms at the interface of ceramic prosthetic materialsJournal of Biomedical Materials Research, 1971
- THE ROLE OF CHEMICAL MEDIATORS IN THE INFLAMMATORY RESPONSE INDUCED BY FOREIGN BODIES: COMPARISON WITH THE SCHISTOSOME EGG GRANULOMAThe Journal of Experimental Medicine, 1970