Assessment of the arterial tonometer (N-CAT) for the continuous blood pressure measurement in rapid atrial fibrillation
Open Access
- 1 April 1993
- journal article
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 40 (4) , 388-393
- https://doi.org/10.1007/bf03009640
Abstract
The N-CAT is a newly developed arterial tonometer (TBP) able to determine systolic, diastolic and mean arterial blood pressures continuously and noninvasively. The aim of this study was to evaluate the accuracy and reliability of TBP relative to directly measured invasive blood pressure (IBP) in ten haemodynamically stable postoperative cardiac patients who were in rapid atrial fibrillation (HR ≥ 100 bpm). There were differences between TBP and IBP for systolic (−1.7 mmHg) and diastolic (+0.9 mmHg) values but not for the mean arterial blood pressures. The N-CAT was able to follow blood pressure changes closely and demonstrated an average systolic, diastolic and mean bias (±SD) of −1.71 ± 4.6, 0.99 ± 4.6 and 0.33 ± 4.2 mmHg, respectively. Although these biases are within the required standards for equivalency for noninvasive blood pressure to invasively determined blood pressure, approximately 20% of the readings were > ±10 mmHg while only 5% were > ±20 mmHg. Moreover, there were occasional discrepancies of sufficient magnitude and duration which may limit the clinical usefulness of the N-CAT in patients in whom continuous and accurate blood pressure measurement is required.Keywords
This publication has 9 references indexed in Scilit:
- Continuous noninvasive blood pressure monitoring during thoracic surgeryJournal of Cardiothoracic and Vascular Anesthesia, 1992
- Continuous Noninvasive Finger Blood Pressure during Controlled Hypotension A Comparison with Intraarterial PressureAnesthesiology, 1991
- COMPARISON OF THE FINAPRES AND DIRECT ARTERIAL PRESSURE MONITORING DURING PROFOUND HYPOTENSIVE ANAESTHESIABritish Journal of Anaesthesia, 1991
- Blood Pressure Measurement by Arterial Tonometry in Controlled HypotensionAnesthesia & Analgesia, 1991
- The Accuracy of Finapres™ Noninvasive Mean Arterial Pressure Measurements in Anesthetized PatientsAnesthesiology, 1991
- The relative accuracies of two automated noninvasive arterial pressure measurement devicesJournal of Clinical Monitoring and Computing, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Arterial tonometry: Review and analysisJournal of Biomechanics, 1983
- Direct Blood Pressure Measurement —Dynamic Response RequirementsAnesthesiology, 1981