Inconsistencies in bioelectrical impedance and anthropometric measurements of fat mass in a field study of prepubertal children
- 1 February 2002
- journal article
- research article
- Published by Cambridge University Press (CUP) in British Journal of Nutrition
- Vol. 87 (2) , 163-175
- https://doi.org/10.1079/bjn2001504
Abstract
The present study examined the consistency of bioelectrical impedance analysis (BIA) and anthropometric measurements in body composition analysis in a field study of prepubertal children using a representative group of 2286 5–7-year-old children from Kiel, north-west Germany. Body composition was assessed using anthropometric measures (A; four skinfolds) and BIA. Various published algorithms (according to and for A, , and for BIA and for a combined approach) were used to estimate body composition. Using A resulted in a sum of four skinfolds varying between age-dependent median values of 24·0 and 28·2 mm in boys and 30·5 and 33·3 mm in girls. When fat mass (FM) was calculated from A, age- and algorithm-dependent differences in median values were observed, with values varying between 8·5 and 14·6 % for boys and 11·1 and 14·9 % for girls. Using different algorithms ( v. ) only minor inconsistencies were observed. BIA-derived resistance index (height2/resistance) varied between 18·8 and 24·4 cm2/Ω for boys and 17·1 and 19·0 cm2/Ω for girls. Using four different algorithms to estimate FM from BIA data resulted in high intra-individual variances in percentage FM (from 13·8 to 33·4) as well as in the prevalence of overweight (from 14·7 to 98·4 % for boys and from 42·3 to 98·5 % for girls). Data obtained using the different BIA algorithms showed some, or even marked, inconsistencies as well as systematic deviations (an overestimation of FM at low percentage FM, v. ). When comparing BIA with A, BIA systematically overestimated FM. The differences between the results were influenced by BMI, gender and height. Considerable inconsistencies were observed at low BMI (<10th percentile) for girls and for small children. Although the within-observer as well as between-observer CV for both techniques are acceptable, we recommend caution in relation to the algorithms used for data analysis. The use of an interchange table of percentage FM derived from different algorithms for different percentile groups of skinfold thicknesses is recommended.Keywords
This publication has 19 references indexed in Scilit:
- Prevention of obesity – is it possible?Obesity Reviews, 2001
- Establishing a standard definition for child overweight and obesity worldwide: international surveyBMJ, 2000
- Gender differences in fat mass of 5–7-year old childrenInternational Journal of Obesity, 1998
- Body mass index and percentage fat mass in healthy German schoolchildren and adolescentsInternational Journal of Obesity, 1998
- Bioelectrical impedance analysis in body composition measurementNutrition, 1996
- Usefulness of Bioelectric Impedance and Skinfold Measurements in Predicting Fat-Free Mass Derived from Total Body Potassium in ChildrenPediatric Research, 1994
- Growth, Maturation, and Physical ActivityMedicine & Science in Sports & Exercise, 1992
- Methodological Difficulties in Studies of Obesity. I. Measurement IssuesAnnals of Behavioral Medicine, 1990
- The assessment of the body fat percentage by skinfold thickness measurements in childhood and young adolescenceBritish Journal of Nutrition, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986