Ion chromatography in series with conductivity detection and inductively coupled plasma-mass spectrometry for the determination of nine halogen, metalloid and non-metal species in drinking water
- 10 May 2001
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (6) , 575-580
- https://doi.org/10.1039/b100783l
Abstract
Ion chromatography (IC) with conductivity detection (ConD) was coupled on-line with inductively coupled plasma-mass spectrometry (ICP-MS) for the purpose of multielement speciation in drinking water. The system allows for the determination of two disinfection by-products (bromate and iodate), their precursors (bromide and iodide), two suspect carcinogenic substances that occur naturally in drinking water (arsenite and arsenate) and three common matrix anions (chloride, nitrate and sulfate). Detection limits, achieved via the direct injection of 100 µL samples, were adequate for the analysis of water intended for human consumption. ICP-MS signal stability and reduced spectroscopic interferences were observed with the use of a membrane suppressor. The IC-ConD-ICP-MS method was used for the analysis of a series of drinking water and spiked drinking water samples. In all samples analysed, bromate and arsenic levels were below the maximum levels set by the US Environmental Protection Agency and the European Commission. Average spike recoveries [±RSD (%)] were 101 ± 1.5% for bromate, 96 ± 17% for bromide, 98 ± 2.8% for arsenic, 98 ± 1.9% for iodate, 91 ± 5% for iodide, 87 ± 5.5% for chloride, 96 ± 1.1% for nitrate and 95 ± 1.8% for sulfate. The method was also used to monitor bromate removal from drinking water following filtration through a domestic water purification unit.Keywords
This publication has 17 references indexed in Scilit:
- Non-spectral interference effects in inductively coupled plasma mass spectrometry using direct injection high efficiency and microconcentric nebulisationJournal of Analytical Atomic Spectrometry, 2000
- Removal of bromate ion from water using granular activated carbonWater Research, 1999
- Bromate removal during transition from new granular activated carbon (GAC) to biological activated carbon (BAC)Water Research, 1999
- Determination of bromate at parts-per-trillion levels by gas chromatography–mass spectrometry with negative chemical ionizationAnalytica Chimica Acta, 1998
- Ultra-trace determination of bromate in drinking waters by means of microbore column ion chromatography and on-line coupling with inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 1998
- Electrospray Ion Chromatography−Tandem Mass Spectrometry of Oxyhalides at Sub-ppb LevelsAnalytical Chemistry, 1998
- An Ion Chromatographic Method for Measuring <5 μg/L Bromate Ion in Drinking WaterAnalytical Chemistry, 1997
- Determination of Bromate in the Presence of Brominated Haloacetic Acids by Ion Chromatography with Inductively Coupled Plasma Mass Spectrometric DetectionEnvironmental Science & Technology, 1997
- Practical applications of element-specific detection by inductively coupled plasma atomic emission spectroscopy and inductively coupled plasma mass spectrometry to ion chromatography of foodsJournal of Chromatography A, 1994
- Ozonation of bromide-containing waters: kinetics of formation of hypobromous acid and bromateEnvironmental Science & Technology, 1983