Silica Xerogel as a Continuous Column Support for High-Performance Liquid Chromatography
- 1 August 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (15) , 2709-2712
- https://doi.org/10.1021/ac951247v
Abstract
A preliminary study of the chromatographic performance and permeability of a continuous silica xerogel column under reversed-phase HPLC conditions was performed. A porous chromatographic support was synthesized inside a 0.32 mm i.d. × 13 cm fused silica tube from potassium silicate solution and derivatized with dimethyloctadecylchlorosilane. The plate height at 0.01 cm/s (0.5 μL/min), near the apparent optimum linear velocity, was about 65 μm. The column efficiencies in terms of numbers of plates per meter were 5000 and 13 000 for ethyl benzoate (k = 0.8) and naphthalene (k = 2.0), respectively, at 0.5 μL/min. The major parameter affecting column efficiency was the heterogeneous morphology of the xerogel, modifications to which are expected to improve chromatographic performance. The column provided efficiencies comparable to those reported for continuous polymeric columns but less than that previously reported for a continuous silica column. Gradient elution mode was demonstrated with a mixture of polycyclic aromatic hydrocarbons. The column was highly permeable, exhibiting a linear dependence of pressure to flow rate and a back pressure of only 632 psi at 10 μL/min when a 95% aqueous mobile phase was used.Keywords
This publication has 9 references indexed in Scilit:
- Molded Monolithic Rod of Macroporous Poly(styrene-co-divinylbenzene) as a Separation Medium for HPLC of Synthetic Polymers: “On-Column” Precipitation−Redissolution Chromatography as an Alternative to Size Exclusion Chromatography of Styrene Oligomers and PolymersAnalytical Chemistry, 1996
- “Molded” rods of macroporous polymer for preparative separations of biological productsBiotechnology & Bioengineering, 1995
- Modified poly(glycidyl metharylate-co-ethylene dimethacrylate) continuous rod columns for preparative-scale ion-exchange chromatography of proteinsJournal of Chromatography A, 1995
- Continuous rods of macroporous polymer as high-performance liquid chromatography separation mediaAnalytical Chemistry, 1992
- Continuous beds: high-resolving, cost-effective chromatographic matricesNature, 1992
- Phase Separation in Gelling Silica–Organic Polymer Solution: Systems Containing Poly(sodium styrenesulfonate)Journal of the American Ceramic Society, 1991
- Flow-through particles for the high-performance liquid chromatographic separation of biomolecules: perfusion chromatographyJournal of Chromatography A, 1990
- Porous ceramic bed supports for fused silica packed capillary columns used in liquid chromatographyJournal of High Resolution Chromatography, 1987
- LSI SPECTROMETRICSAnalytical Chemistry, 1973