X-Ray Response of National Ignition Facility First Surface Materials
- 1 November 1994
- journal article
- research article
- Published by Taylor & Francis in Fusion Technology
- Vol. 26 (3P2) , 804-808
- https://doi.org/10.13182/fst94-a40253
Abstract
The ablation of first surface materials by x rays is a primary threat to the final optics in the NIF target chamber. To meet the operational goals of the facility, the designs of the chamber wall, target holder, and diagnostic surfaces must minimize ablation by x rays, typically by specifying materials that are low-Z, high temperature resistant, and shock resistant. Additionally, the response of the optics to direct target emissions must be understood. This paper describes some experimental and modeling work to develop the validated computer models necessary to quantify the x-ray response of various materials. These codes and further experiments will then confirm the ability of NIF first surface designs to meet functional requirements.Keywords
This publication has 4 references indexed in Scilit:
- DYNA3D: A nonlinear, explicit, three-dimensional finite element code for solid and structural mechanics, User manual. Revision 1Published by Office of Scientific and Technical Information (OSTI) ,1993
- Nova upgrade design support threats from radiation effects in the proposed nova upgradePublished by Office of Scientific and Technical Information (OSTI) ,1992
- Blast Venting through Blanket Material in the HYLIFE ICF ReactorFusion Technology, 1992