Comparison of Reverse-Geometry Lens Designs for Overnight Orthokeratology
- 1 December 2003
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Optometry and Vision Science
- Vol. 80 (12) , 796-804
- https://doi.org/10.1097/00006324-200312000-00009
Abstract
The efficacy of overnight wear of four types of reverse-geometry lenses was compared. The length of time needed to achieve correction and any adverse events that occurred during the course of the study were recorded. In this prospective, randomized study, 60 subjects (18 to 35 years old) with refractive error between -1.00 to -4.00 D (cyl </= -1.50) wore reverse-geometry lenses overnight only. All subjects were assigned a Rinehart Reeves lens in one eye, and subsets of 20 subjects were randomly assigned a Mountford BE, DreimLens, or Contex D Series 4 lens for the contralateral eye. Visits included baseline, dispensing, 1 day, 1 week, and 1 month. Biomicroscopy, unaided visual acuity, subjective refraction, best-corrected visual acuity at high and low contrast and high and low illumination, corneal topography, and subjective rating data were collected. Forty-six subjects completed the study. At 1 month, there were no significant differences between lens types in their effect on unaided visual acuity, subjective sphere, subjective cylinder, best-corrected visual acuity at high and low contrast at high illumination and low contrast at low illumination, apical corneal radius, corneal eccentricity, and subjective ratings. Between 1 week and 1 month, there was a significant improvement in subjective ratings of quality of day and night vision (p < 0.05) but no significant change in the objective measures. No significant ocular adverse events were observed during the trial. The lens types tested were all similarly effective in the reduction of myopic refractive error. Subjective ratings continued to improve after objective measures stabilized at 1 week. Overnight lens wear proceeded for 1 month without significant adverse reactions.Keywords
This publication has 12 references indexed in Scilit:
- Overnight Orthokeratology: Preliminary Results of the Lenses and Overnight Orthokeratology (LOOK) StudyOptometry and Vision Science, 2002
- Infectious keratitis in orthokeratologyClinical & Experimental Ophthalmology, 2002
- Serratia marcescens corneal ulcer as a complication of orthokeratologyAmerican Journal of Ophthalmology, 2001
- Overnight OrthokeratologyOptometry and Vision Science, 2000
- Corneal Response to OrthokeratologyOptometry and Vision Science, 1998
- Assessment of High and Low Contrast Visual Acuity after Photorefractive Keratectomy for MyopiaOptometry and Vision Science, 1998
- Orthokeratology — an alternative to excimer laser?Journal of The British Contact Lens Association, 1995
- The Berkeley Orthokeratology Study, Part IIOptometry and Vision Science, 1983
- An Evaluation of OrthokeratologyOphthalmology, 1980
- New Design Principles for Visual Acuity Letter ChartsOptometry and Vision Science, 1976