Amperometric Determination of Total Cholesterol at Gold Electrodes Covalently Modified with Cholesterol Oxidase and Cholesterol Esterase with Use of Thionin as an Electron Mediator
- 29 January 1999
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 71 (5) , 1068-1076
- https://doi.org/10.1021/ac9805450
Abstract
Immobilization of cholesterol oxidase (EC 1.1.3.6) (ChOx) on a gold electrode was attempted by cross-linking using glutaraldehyde between ChOx molecules and a self-assembled monolayer of 2-aminoethanethiolate. The resulting electrode (ChOx/Au) exhibits an amperometric response to free cholesterol in the presence of thionin as an electron mediator, and a steady-state response is obtained ∼60 s after injection of cholesterol into the electrolyte solution. Coimmobilization of cholesterol esterase (EC 3.1.1.13) (ChE) and ChOx (ChE/ChOx/Au) allows the amperometric determination of both esterified cholesterol and free cholesterol. Cyclic voltammetry of the ChE/ChOx/Au and the dependence of the amperometric response to cholesterol on the concentration of thionin suggest that thionin is encapsulated in the enzyme film on the electrode surface. Apparent Michaelis constants of the ChOx/Au and the ChE/ChOx/Au electrodes suggest that the amperometric response was controlled by penetration of the reaction substrate into the films of the enzyme(s). The concentration of total (free and esterified) cholesterol in human serum samples, determined by using the techniques developed in the present study, is in good agreement with that determined by the well-established technique using colorimetry.Keywords
This publication has 38 references indexed in Scilit:
- Electrical contact of redox enzyme layers associated with electrodes: Routes to amperometric biosensorsElectroanalysis, 1997
- Electrochemistry of Surface-Confined Mixed Monolayers of 4-Aminothiophenol and Thiophenol on AuLangmuir, 1996
- Use of an Electrodeposited Avidin Film for the Preparation of Lactate and Choline SensorsAnalytical Sciences, 1995
- Measurement of equilibrium constants for the formation of esters from aliphatic carboxylic acids and alcoholsAnalytical Chemistry, 1994
- Enzyme catalysis at hydrogel-modified electrodes with soluble redox mediatorJournal of the Chemical Society, Faraday Transactions, 1994
- Near-infrared diode laser spectroscopy of the nitrogen molecule in Rydberg statesThe Journal of Chemical Physics, 1991
- Crystal structure of cholesterol oxidase from Brevibacterium sterolicum refined at 1.8 Å resolutionJournal of Molecular Biology, 1991
- Glucose Oxidase-Immobilized Benzoquinone-Mixed Carbon Paste Electrode with Pre-MinigridAnalytical Sciences, 1985
- Amperometric determination of total cholesterol in serum with use of immobilized cholesterol esterase and cholesterol oxidaseAnalytica Chimica Acta, 1982
- Molecular weight estimation of polypeptide chains by electrophoresis in SDS-polyacrylamide gelsBiochemical and Biophysical Research Communications, 1967