Sensitivity, specificity and predictive value of clinical findings, m-mode echocardiography and continuous-wave Doppler sonography in the diagnosis of symptomatic patent ductus arteriosus in preterm infants
- 31 March 1988
- journal article
- research article
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 147 (3) , 279-282
- https://doi.org/10.1007/bf00442695
Abstract
By means of probability analysis we have compared the diagnostic value of clinical symptoms, m-mode echocardiographic measurements and peripheral arterial flow, assessed by continuous-wave Doppler, in preterm infants with symptomatic patent ductus arteriosus (PDA). Data were obtained in 29 infants with PDA and in 29 controls. The most sensitive clinical finding was a hyperactive precordium. Bounding pulses and a heart murmur were absent in 15% and 20%, respectively of the patients with PDA. M-mode echocardiographic measurements were rather specific for the detection of a PDA but less sensitive. Diastolic backflow in the brachial and femoral arteries was present in the majority of patients with PDA and absent in about 67% of the controls. The values in probability analysis, however, were too low to base a therapy on these findings. The highest sensitivity and specificity (100% each) was found for a disturbed cerebral blood flow with absent or retrograde diastolic perfusion estimated by Doppler sonography.Keywords
This publication has 20 references indexed in Scilit:
- Left ventricular performance and regional blood flows before and after ductus arteriosus occlusion in premature lambs treated with surfactant.Circulation, 1983
- Cerebral blood flow velocity in relation to intraventricular hemorrhage in the premature newborn infantThe Journal of Pediatrics, 1982
- Continuous wave Doppler ultrasonographic quantitation of patent ductus arteriosus flowThe Journal of Pediatrics, 1982
- The effect of patent ductus arteriosus on flow velocity in the anterior cerebral arteries: Ductal steal in the premature newborn infantThe Journal of Pediatrics, 1981
- Doppler ultrasonography in evaluation of PDA shuntingThe Journal of Pediatrics, 1981
- Specificity and accuracy of echocardiographic and clinical criteria for diagnosis of patent ductus arteriosus in fluid-restricted infantsThe Journal of Pediatrics, 1981
- Noninvasive detection of retrograde descending aortic flow in infants using continuous wave Doppler ultrasonographyThe Journal of Pediatrics, 1980
- Pulsatile aortopulmonary pressure-flow dynamics of patent ductus arteriosus in patients with various hemodynamic states.Circulation, 1980
- Noninvasive diagnosis of neonatal asphyxia and intraventricular hemorrhage by Doppler ultrasoundThe Journal of Pediatrics, 1979