Storage and elimination of titanium, aluminum, and vanadium salts, in vivo
- 1 November 1992
- journal article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 26 (11) , 1503-1515
- https://doi.org/10.1002/jbm.820261109
Abstract
Hamsters were injected with titanium, aluminum, and vanadium salts either intraperitoneally or intramuscularly to study the transport, storage, and elimination of these metals. Blood samples were taken at 4 h or 24 h, and urine samples were taken a t 24, 48, and 72 h. The hamsters were then injected weekly for 5 weeks after the initial injection. Blood and portions of the kidneys, liver, lung, and spleen were taken at sacrifice. All samples were analyzed for titanium, aluminum, and vanadium concentrations using graphite furnace atomic absorption spectroscopy (GFAAS). Titanium was found not to be excreted in the urine, was found in low levels in the blood, and was elevated over control in the kidney, liver, and spleen. Aluminum detection via GFAAS showed wide standard deviations and high levels in controls; however, aluminum was found to be excreted in the urine, and to be transported by the blood in the experimental animals. A small amount accumulated in the liver and spleen. Vanadium was excreted in high levels in the urine. A small amount was found in the blood, and the level in the organs was below the reliable detection limits. The rapid excretion of vanadium might be related to its solubility in physiological conditions, while the limited excretion of titanium may be related to its being insoluble in the physiologic environment. © 1992 John Wiley & Sons, Inc.Keywords
This publication has 16 references indexed in Scilit:
- In vitroandin vivometal ion releaseJournal of Biomedical Materials Research, 1988
- The biological response to titanium and titanium-aluminium-vanadium alloy particlesBiomaterials, 1986
- The biological response to titanium and titanium-aluminium-vanadium alloy particlesBiomaterials, 1985
- Blood distribution of nickel, cobalt, and chromium following intramuscular injection into hamstersJournal of Biomedical Materials Research, 1984
- Release of corrosion products by F‐75 cobalt base alloy in the rat. I: Acute serum elevationsJournal of Biomedical Materials Research, 1984
- In vivo metal‐ion release from porous titanium‐fiber materialJournal of Biomedical Materials Research, 1984
- Isolation of serum protein organometallic corrosion products from 316LSS and HS‐21 in vitro and in vivoJournal of Biomedical Materials Research, 1984
- Behavior of Commercially Pure Titanium and Ti-318 (Ti-6Al-4V) in Orthopedic ImplantsPublished by ASTM International ,1983
- Metal ion release from titanium‐based prosthetic segmental replacements of long bones in baboons: A long‐term studyJournal of Orthopaedic Research, 1983
- Metal Sensitivity Reactions to Orthopedic ImplantsInternational Journal of Dermatology, 1981