Some angular| dependences of the ion-electron emission coefficient

Abstract
In the cases when primary ion beam direction is aligned with close-packed planes the dependences of the reduced coefficient of ion-electron emission on various angles has been studied. It was found that there are such ranges of azimuthal angle and angle of incidence of primary ion beam within which the reduced coefficient is determined mainly by the angle between the primary ion beam and close-packed plane only.