Responding to Chicago newspaper reports, measurements of blood pressure by a publicly available, automated coin-operated device were compared with those of human observers using the standard cuff and auscultatory technique. One machine was examined in the laboratory, and eight others at randomly selected sites. Analysis of readings made on 100 persons in the laboratory and 227 in the field led to the following conclusions: 1) On the average, the machines measured fifth phase diastolic blood pressure at nearly the same level as did human observers; 2) The machines were more variable measuring systolic blood pressure with four differing from the average human reading by 1mm Hg or less, but two differing by 8mm Hg or more; 3) The agreement between machine-human pairs of readings was not as good as between human-human pairs, but the differences in level of agreement--both in determining the actual value and in categorizing the values as normal, borderline, or high--were small and have little practical importance; 4) Linear regression analyses of the relationship between simultaneously determined machine and human readings indicated that the average human-machine difference was the same over the range of pressures tested. Publicly available blood pressure measuring devices should be labeled concerning their purposes, capabilities, and limitations. Rules and regulations governing their use in the City of Chicago are being prepared by this city's Legal Department.Keywords
This publication has 16 references indexed in Scilit:
- Blood Pressure Studies in 14 CommunitiesPublished by American Medical Association (AMA) ,1977
- The Measurement of Observer Agreement for Categorical DataPublished by JSTOR ,1977
- Hypertension Screening of 1 Million AmericansPublished by American Medical Association (AMA) ,1976
- Hypertension screening of 1 million Americans. Community Hypertension Evaluation Clinic (CHEC) program, 1973 through 1975JAMA, 1976
- Evaluation of performance of selected devices for measuring blood pressureThe American Journal of Cardiology, 1973
- Current status of hypertension control in an industrial populationJAMA, 1972
- Effects Morbidity of Treatment on in HypertensionJAMA, 1970
- A general method for analysis of covariance structuresBiometrika, 1970
- Effects of Treatment on Morbidity in HypertensionJAMA, 1967
- Recommendations for Human Blood Pressure Determination by SphygmomanometersCirculation, 1967