Nine-Analyte Detection Using an Array-Based Biosensor
- 31 October 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (23) , 6114-6120
- https://doi.org/10.1021/ac0260185
Abstract
A fluorescence-based multianalyte immunosensor has been developed for simultaneous analysis of multiple samples. While the standard 6 × 6 format of the array sensor has been used to analyze six samples for six different analytes, this same format has the potential to allow a single sample to be tested for 36 different agents. The method described herein demonstrates proof of principle that the number of analytes detectable using a single array can be increased simply by using complementary mixtures of capture and tracer antibodies. Mixtures were optimized to allow detection of closely related analytes without significant cross-reactivity. Following this facile modification of patterning and assay procedures, the following nine targets could be detected in a single 3 × 3 array: Staphylococcal enterotoxin B, ricin, cholera toxin, Bacillus anthracis Sterne, Bacillus globigii, Francisella tularensis LVS, Yersinia pestis F1 antigen, MS2 coliphage, and Salmonella typhimurium. This work maximizes the efficiency and utility of the described array technology, increasing only reagent usage and cost; production and fabrication costs are not affected.Keywords
This publication has 30 references indexed in Scilit:
- Dissecting glucose signalling with diversity-oriented synthesis and small-molecule microarraysNature, 2002
- An fMRI Investigation of Emotional Engagement in Moral JudgmentScience, 2001
- Micromosaic ImmunoassaysAnalytical Chemistry, 2000
- Protein Microchips: Use for Immunoassay and Enzymatic ReactionsAnalytical Biochemistry, 2000
- Printing Small Molecules as Microarrays and Detecting Protein−Ligand Interactions en MasseJournal of the American Chemical Society, 1999
- Highly parallel affinity sensor for the detection of environmental contaminants in water1Parts of this work were presented at the Fifth World Congress on Biosensors, Berlin, Germany, 1998.1Analytica Chimica Acta, 1999
- Protein Microarrays for Gene Expression and Antibody ScreeningAnalytical Biochemistry, 1999
- Patterned planar array immunosensor for multianalyte detectionJournal of Biomedical Optics, 1997
- Use of thiol-terminal silanes and heterobifunctional crosslinkers for immobilization of antibodies on silica surfacesAnalytical Biochemistry, 1989
- Antigenic Structure of Pasteurella pestis and the Isolation of a Crystalline Antigen.*Experimental Biology and Medicine, 1947