Trace ion analysis of seawater by capillary electrophoresis: Determination of iodide using transient isotachophoretic preconcentration
- 16 July 2003
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 24 (14) , 2328-2334
- https://doi.org/10.1002/elps.200305445
Abstract
An improved transient isotachophoresis (tITP) procedure for the preconcentration of iodide from highly saline matrices was developed with the objective to quantify iodide in seawater by capillary electrophoresis (CE). The procedure takes advantage of introducing cetyltrimethylammonium chloride into the high-sodium chloride background electrolyte, which due to a specific interaction with iodide amended placement of the analyte at a large distance from the matrix chloride (the latter performed the role of a leading anion). Computer simulation showed that 2-(N-morpholino)ethanesulfonate could be adopted as a suitable terminating ion to enable isotachophoretic focusing at the beginning of the CE run. Under optimized tITP conditions, the sensitivity response of iodide was improved by a factor of 140 over normal CE mode. This allowed for direct UV detection of as low as 0.6 μg/L iodide and made feasible CE analysis of undiluted surface seawater samples where iodide was found at a 30 μg/L level. The applicability of the proposed tITP-CE method could apparently be extended to the determination of other trace seawater anions (e.g., iodate).Keywords
This publication has 19 references indexed in Scilit:
- Manipulation of separation selectivity in capillary zone electrophoresis of anionic solutesTrAC Trends in Analytical Chemistry, 2001
- Enhanced Detection of Iodide in Seawater by Ion Chromatography Using an ODS Column Coated with CetyltrimethylammoniumAnalytical Sciences, 2001
- Inorganic environmental analysis by capillary electrophoresisThe Analyst, 1999
- Separation of inorganic anions for analysis of sea-water by capillary zone electrophoresisAnalytical Communications, 1999
- Capillary electrophoresis of anions at high salt concentrationsElectrophoresis, 1998
- Determination of Iodide in Seawater by Ion ChromatographyAnalytical Chemistry, 1997
- Computer simulation and experimental evaluation of on-column sample preconcentration in capillary zone electrophoresis by discontinuous buffer systemsAnalytical Chemistry, 1993
- Effects of carrier electrolyte composition on separation selectivity in capillary zone electrophoresis of low- molecular-mass anionsJournal of Chromatography A, 1992
- Direct determination of iodide in seawater by cathodic stripping square wave voltammetryAnalytical Chemistry, 1988
- Automatic determination of iodine species in natural waters by a new flow-through electrode systemAnalytical Chemistry, 1985