Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
- 1 August 2003
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 35 (8) , 1447-1454
- https://doi.org/10.1249/01.mss.0000079078.62035.ec
Abstract
To evaluate the reliability and validity of the CSA (model 7164) accelerometer (MTI) in a wide walking-running speed range in laboratory and field. Twelve male subjects performed three treadmill walking/running sessions and one field trial with the same continuous protocol involving progressively increasing velocities at 5 min per interval from 3 to 6 km x h(-1) (walking) and 8 to 20 km x h(-1) (running). In the field trial, this protocol was terminated after 35 min (14 km.h(-1)), but the trial then extended with 5-km running at a freely chosen velocity. In both scenarios, two CSAs were mounted on each hip and the step frequency measured at each velocity. Oxygen uptake VO(2) x kg(-1) was measured on the last two treadmill sessions. Correlation analyses were performed for mean CSA output relationship with speed, VO(2) per kilogram, and step frequency. In all trials, CSA output rose linearly (R2 = 0.92, P < 0.001) with increasing speed until 9 km.h-1 but remained at approximately 10000 counts.min-1 during running, thus underestimating VO(2) per kilogram at speeds > 9 km x h(-1). Estimation errors increased with speed from 11% (P < 0.01) at 10 km x h(-1) to 48% (P < 0.001) at 16 km x h(-1), when assuming a linear relationship. Freely chosen velocities in the field trial ranged from 10.9 to 16.3 km.h-1. No difference in the CSA-speed relationship was observed between the two scenarios. Differences in CSA output between subjects could partially be attributed to differences in step frequency (R = -0.34 (P = 0.02) for walking and R = -0.63 (P < 0.001) for running). CSA output increases linearly with speed in the walking range but not in running, presumably due to relatively constant vertical acceleration in running. Between-subject reliability was related to step frequency because CSA data are filtered most at higher movement frequencies. Epidemiological CSA data should thus be interpreted with these limitations in mind.Keywords
This publication has 34 references indexed in Scilit:
- Reliability and Validity of the Computer Science and Applications Accelerometer in a Mechanical SettingMeasurement in Physical Education and Exercise Science, 2003
- Energy cost and running mechanics during a treadmill run to voluntary exhaustion in humansEuropean Journal of Applied Physiology, 1998
- The longitudinal development of running economy in males and females aged between 13 and 27 years: The Amsterdam Growth and Health StudyEuropean Journal of Applied Physiology, 1997
- Biomechanics and Running EconomySports Medicine, 1996
- Mechanical step variability during treadmill runningEuropean Journal of Applied Physiology, 1995
- The determinants of the step frequency in running, trotting and hopping in man and other vertebrates.The Journal of Physiology, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Mechanical work and efficiency in level walking and runningThe Journal of Physiology, 1977
- The sources of external work in level walking and running.The Journal of Physiology, 1976
- Mechanics of walking.Journal of Applied Physiology, 1966