Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents
- 29 February 1996
- journal article
- research article
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 334 (9) , 561-567
- https://doi.org/10.1056/nejm199602293340903
Abstract
Coronary-artery stents are known to reduce rates of restenosis after coronary angioplasty, but it is uncertain how long this benefit is maintained. We evaluated clinical and angiographic follow-up information for up to three years after the implantation of Palmaz–Schatz metallic coronary-artery stents in 143 patients with 147 lesions of native coronary arteries. The rate of survival free of myocardial infarction, bypass surgery, and repeated coronary angioplasty for stented lesions was 74.6 percent at three years. After 14 months, revascularization of the stented lesion was necessary in only three patients (2.1 percent). In contrast, coronary angioplasty for a new lesion was required in 11 patients (7.7 percent). Follow-up coronary angiography of 137 lesions at six months, 114 lesions at one year, and 72 lesions at three years revealed a decrease in minimal luminal diameter from 2.54±0.44 mm immediately after stent implantation to 1.87±0.56 mm at six months, but no further decrease in diameter at one year (in patients with paired angiograms, 1.95±0.49 mm at both six months and one year). Significant late improvement in luminal diameter was observed at three years (in patients with paired angiograms, 1.94±0.48 mm at six months and 2.09±0.48 mm at three years; P<0.001). Clinical and angiographic outcomes up to three years after coronary-artery stenting were favorable, with a low rate of revascularization of the stented lesions. Late improvement in luminal diameter appears to occur between six months and three years.Keywords
This publication has 26 references indexed in Scilit:
- Four-year experience with Palmaz-Schatz stenting in coronary angioplasty complicated by dissection with threatened or present vessel closure.Circulation, 1994
- A Comparison of Balloon-Expandable-Stent Implantation with Balloon Angioplasty in Patients with Coronary Artery DiseaseNew England Journal of Medicine, 1994
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- Serial angiographic follow-up after palmaz-schatz stent implantation: Comparison with conventional balloon angioplastyJournal of the American College of Cardiology, 1993
- Restenosis after placement of Palmaz-Schatz stents in native coronary arteries. Initial results of a multicenter experience.Circulation, 1992
- Emergent use of balloon-expandable coronary artery stenting for failed percutaneous transluminal coronary angioplasty.Circulation, 1992
- Angiographic and clinical outcome of intracoronary stenting: Immediate and long-term results from a large single-center experienceJournal of the American College of Cardiology, 1992
- Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty.Circulation, 1992
- Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study.Circulation, 1991
- Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal AngioplastyNew England Journal of Medicine, 1987