Relationship of A1C to Glucose Concentrations in Children With Type 1 Diabetes
Open Access
- 1 March 2008
- journal article
- Published by American Diabetes Association in Diabetes Care
- Vol. 31 (3) , 381-385
- https://doi.org/10.2337/dc07-1835
Abstract
OBJECTIVE—Despite the standing of A1C as the most validated and widely used measure for average glycemic control over time, the relationship between A1C and glucose concentrations is not completely understood. The purpose of this Diabetes Research in Children Network (DirecNet) study was to use continuous glucose monitoring data to examine the relationship between A1C and glucose in type 1 diabetes. RESEARCH DESIGN AND METHODS—Forty-eight youth enrolled in studies of the Navigator continuous glucose monitor were encouraged to wear the Navigator sensor at home continuously. A1C was measured at baseline, at 3 months, and at 6 months. Sensor glucose data were directly transmitted via the Internet, assuring that essentially all glucose values were analyzed. RESULTS—Subjects had a median of 112 h/week of Navigator data in the first 3 months and 115 h/week in the second 3 months. The slope of mean glucose over the previous 3 months versus A1C was only 18 mg/dl per 1.0% A1C. Individually, there was substantial variation in the relationship between mean glucose and A1C. A1C was not associated with glucose lability after controlling for mean glucose. Measures of an individual's rate of glycation were moderately correlated at the 3- and 6-month visits. CONCLUSIONS—As the chemistry of glycation would predict, we found no evidence to contradict the simple hypothesis that A1C directly reflects mean glucose over time. There is, however, substantial variability in individual mean glucose concentrations for a given A1C. Transforming reliable A1C values into calculated mean glucose values would, when applied to an individual, introduce substantial error.Keywords
This publication has 17 references indexed in Scilit:
- Relationship between glycated haemoglobin levels and mean glucose levels over timeDiabetologia, 2007
- Eight-Point Glucose Testing Versus the Continuous Glucose Monitoring System in Evaluation of Glycemic Control in Type 1 DiabetesJournal of Clinical Endocrinology & Metabolism, 2005
- Comparison of fingerstick hemoglobin A1c levels assayed by DCA 2000 with the DCCT/EDIC central laboratory assay: results of a Diabetes Research in Children Network (DirecNet) StudyPediatric Diabetes, 2005
- Biological Variation in HbA1c Predicts Risk of Retinopathy and Nephropathy in Type 1 DiabetesDiabetes Care, 2004
- Is Poor Glycemic Control Associated With Reduced Red Blood Cell Lifespan?Diabetes Care, 2004
- What is the relative contribution of blood glucose levels at different time points of the day to HbA1c in Type 1 diabetes?Diabetic Medicine, 2004
- Defining the Relationship Between Plasma Glucose and HbA1cDiabetes Care, 2002
- Nonfasting Plasma Glucose is a Better Marker of Diabetic Control Than Fasting Plasma Glucose in Type 2 DiabetesDiabetes Care, 1997
- Unexplained variability of glycated haemoglobin in non-diabetic subjects not related to glycaemiaDiabetologia, 1990
- Mean Amplitude of Glycemic Excursions, a Measure of Diabetic InstabilityDiabetes, 1970