Safety of Single Transseptal Puncture for Ablation of Atrial Fibrillation: Retrospective Study from a Large Cohort of Patients
- 25 October 2007
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 18 (12) , 1277-1281
- https://doi.org/10.1111/j.1540-8167.2007.00958.x
Abstract
Introduction: Transseptal puncture (TSP) is the conventional approach to assess the left atrial chamber. This technique has been widely used in interventional cardiology and, in the last years, this approach is mostly applied to electrophysiologic procedures. For atrial fibrillation (AF) ablation, two or more transseptal sheaths are often positioned in the left atrium in the majority of centers, therefore requiring two or more transseptal punctures. Theoretically, double puncture could bear additional risks or could increase the risk of persistence of septal defects. We reported the results of a retrospective analysis of a single transseptal puncture as a simplified approach for positioning multiple catheters in the left atrium during AF ablation. Methods: Between November 2003 and November 2005, 1,150 consecutive patients (mean age 54 ± 8 years, 75% men) were considered for AF ablation and underwent single transseptal puncture for positioning multiple catheters in the left atrium. Results: In only 6 of 1,150 (0.5%) cases a second transseptal puncture was required to position the ablation catheter in the left atrium. Neither acute complications related to transseptal catheterization such as atrial or aortic perforations, pericardial tamponade, thrombotic formation, or air embolism, nor complications due to the attempts of crossing the septum with the ablation catheter were reported. In all cases, each mapping catheter was properly maneuvered at different sites in the left atrium and at the pulmonary veins. In no patient was a residual septal atrial defect after the transseptal maneuvers detected during a mean follow up of 14 ± 2 months. Conclusions: This retrospective study on a large cohort of patients shows that single transseptal puncture for positioning two or more catheters in the left atrium for AF ablation is a highly successful and safe maneuver with a very low morbidity in the majority of patients. This may avoid potential complications related to a second transseptal puncture.Keywords
This publication has 21 references indexed in Scilit:
- Repeat Transseptal Catheterization After Ablation for Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Intracardiac Ultrasound Detection of Thrombus on Transseptal Sheath: Incidence, Treatment, and PreventionJournal of Cardiovascular Electrophysiology, 2005
- Persistence of Septal Defects After Transeptal Puncture for Pulmonary Vein Isolation ProceduresPacing and Clinical Electrophysiology, 2004
- High‐Flow Perfusion of Sheaths for Prevention of Thromboembolic Complications During Complex Catheter Ablation in the Left AtriumJournal of Cardiovascular Electrophysiology, 2004
- Plasma von Willebrand factor, fibrinogen and soluble P-selectin levels in paroxysmal, persistent and permanent atrial fibrillation. Effects of cardioversion and return of left atrial functionPublished by Oxford University Press (OUP) ,2001
- Intracardiac Echocardiography to Guide Transseptal Left Heart Catheterization for Radiofrequency Catheter AblationJournal of Cardiovascular Electrophysiology, 1999
- The technique and safety of transseptal left heart catheterization: the massachusetts general hospital experience with 1,279 proceduresCatheterization and Cardiovascular Diagnosis, 1994
- Transseptal catheterization update 1992Catheterization and Cardiovascular Diagnosis, 1992
- Prevalence of Patent Foramen Ovale in Patients with StrokeNew England Journal of Medicine, 1988
- Transseptal left atrial puncture: New technique for the measurement of left atrial pressure in manThe American Journal of Cardiology, 1959