Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies
- 8 January 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (1) , 36-45
- https://doi.org/10.1118/1.1333411
Abstract
Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo targets. Mixture activities at the end of bombardment were determined with a calibrated high purity germanium detector. The activity fractions of the greatest mixture impurities relative to 100% for Tc-94m averaged 10.0% (Tc-94g) and 3.3% (Tc-93) for enriched targets and 10.1% (Tc-94g), 11.0% (Tc-95), 255.8% (Tc-96m), and 7.2% (Tc-99m) for natural targets. These radioisotopes have different half-lives (e.g., 52.5 min for Tc-94m, 293 min for Tc-94g), positron branching ratios (e.g., 0.72 for Tc-94m, 0.11 for Tc-94g) and gamma ray emissions for themselves and their short-lived, excited Mo daughters. This complicates estimation of injected activity with a dose calibrator, in vivo activity with PET and blood sample activity with a gamma counter. Decay correction using only the Tc-94m half-life overestimates activity and is inadequate. For this reason analytic formulas for activity estimation and decay correction of radionuclide mixtures were developed. Isotope-dependent sensitivity factors for a PET scanner, dose calibrator, and gamma counter were determined using theoretical sensitivity models and fits of experimental decay curves to sums of exponentials with fixed decay rates. For up to 8 h after the end of bombardment with activity from enriched and natural Mo targets, decay-corrected activities were within 3% of the mean for three PET studies of a uniform cylinder, within 3% of the mean for six dose calibrator decay studies, and within 6% of the mean for four gamma counter decay studies. Activity estimation and decay correction for Tc-94m mixtures enable routine use of Tc-94m in quantitative PET, as illustrated by application to a canine Tc-94m sestamibi study.Keywords
This publication has 9 references indexed in Scilit:
- Comparison of fluorine-18 and bromine-76 imaging in positron emission tomographyEuropean Journal of Nuclear Medicine and Molecular Imaging, 1999
- Production cross sections of ground and isomeric states in the reaction systemsandPhysical Review C, 1997
- Improving the radionuclidic purity of 94mTc for PET imagingApplied Radiation and Isotopes, 1995
- Excitation Functions of α-Particle Induced Nuclear Reactions on Highly Enriched 92Mo: Comparative Evaluation of Production Routes for 94mTcRadiochimica Acta, 1995
- Technetium 94m-labeled methoxyisobutyl isonitrile: Dosimetry and resting cardiac imaging with positron emission tomographyJournal of Nuclear Cardiology, 1994
- Excitation Functions of 93Nb(3He,xn)93m,g, 94 m,g, 95m,gTc-Processes from Threshold up to 35 MeV: Possibility of Production of 94mTc in High Radiochemical Purity using a Thermochromatographic Separation TechniqueRadiochimica Acta, 1994
- Thermochromatographic Separation of 94mTc from Enriched Molybdenum Targets and its Large Scale Production for Nuclear Medical ApplicationRadiochimica Acta, 1994
- Nuclear Data Relevant to the Production of the Positron Emitting Technetium Isotope 94mTc via the 94Mo(p,n)-reactionRadiochimica Acta, 1993
- Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the ProjectionsJournal of Computer Assisted Tomography, 1983