Ventilator-Related Acinetobacter Outbreak in an Intensive Care Unit
Open Access
- 1 June 1998
- journal article
- research article
- Published by Oxford University Press (OUP) in Military Medicine
- Vol. 163 (6) , 389-391
- https://doi.org/10.1093/milmed/163.6.389
Abstract
An outbreak of 16 cases of ciprofloxacin-resistant Acinetobacter baumannii (calcoaceticus subspecies anitratus) infections occurred during a 7-month period in a medical intensive care unit. Fifteen of the patients developed pneumonia associated with ventilator support. Possible sources considered in the outbreak investigation were sinks, ice, personnel, patients on multiple antibiotic therapy, reusable ventilator circuits, and hemodialysis. The equipment and environment associated with the outbreak were cultured. Patients on ventilators were significantly more susceptible to Acinetobacter nosocomial infection compared with the rest of the patients in the medical intensive care unit (p < 0.05). Sputum cultures were only 5% sensitive to ciprofloxacin and gentamicin, but they were 100% sensitive to imipenem (p < 0.0001). Uncloaking imipenem was a significant contributing factor in controlling this outbreak. Once outbreak control measures were instituted, Acinetobacter isolates dropped from 77 (during the outbreak year) to 9 (during the subsequent year) and no new pneumonia cases occurred.Keywords
This publication has 0 references indexed in Scilit: