During a 24-month period, 5,625 blood culture specimens were collected at the Seattle Veterans Administration Medical Center in 20-ml volumes and divided into separate 10-ml aliquots. The two aliquots were processed as duplicate sets (set 1, set 2) by the BACTEC system (Johnston Laboratories, Inc., Towson, Md.). Specimens (5 ml) from each set were inoculated into aerobic (6B) and anaerobic (7C/7D) vials. A total of 434 significantly positive blood cultures were found. In 342 of these positive cultures, yielding 379 isolates (112 members of the family Enterobacteriaceae, 104 staphylococci, 87 streptococci, 27 anaerobes, 20 yeasts, 14 pseudomonads, and 15 miscellaneous organisms), there was adequate specimen volume to fill all four vials. The utilization of set 1 would have resulted only in the failure to detect 65 of 379 (17.2%) significant isolates, 52 of 342 (15.2%) positive cultures, and 20 of 198 (10.1%) bacteremic episodes. There were no significant differences in the recovery of individual species in sets 1 and 2. Although the range of isolates recovered by the aerobic and anaerobic vials of each set differed, the percent yield of total isolates was similar, indicating total isolate yield was predominantly a function of specimen volume. The addition of set 2 most dramatically increased the recovery of Escherichia coli (30%), yeasts (33%), and anaerobes (42%).This publication has 13 references indexed in Scilit:
- Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture mediaJournal of Clinical Microbiology, 1984
- Laboratory experience with radiometric detection of bacteremia with three culture mediaJournal of Clinical Microbiology, 1984
- Effect of volume of blood cultured on detection of Streptococcus viridans bacteraemia.Journal of Clinical Pathology, 1984
- The importance of volume of blood cultured in the detection of bacteremia and fungemiaPublished by Elsevier ,1983
- Controlled evaluation of the volume of blood cultured in detection of bacteremia and fungemiaJournal of Clinical Microbiology, 1982
- THE IMPORTANCE OF BLOOD VOLUME CULTURED ON DETECTION OF BACTERAEMIAActa Pathologica Microbiologica Scandinavica Section B Microbiology, 1981
- Effect of blood dilution on recovery of organisms from clinical blood cultures in medium containing sodium polyanethol sulfonateJournal of Clinical Microbiology, 1979
- Effect of volume of blood cultured on detection of bacteremiaJournal of Clinical Microbiology, 1976