Radial dose distribution, dose to water and dose rate constant for monoenergetic photon point sources from 10 keV to 2 MeV: EGS4 Monte Carlo model calculation
- 10 December 1999
- journal article
- Published by Wiley in Medical Physics
- Vol. 26 (12) , 2531-2538
- https://doi.org/10.1118/1.598790
Abstract
A comprehensive set of dose distributions from monoenergetic photon‐emitting isotropic point sources in a medium can be used as a reference database for the dosimetry of photon emitter sources in that medium. Data of this type for water over the photon energy range from 15 keV to 2 MeV have been published based on calculations using a one‐dimensional photon transport model. The present work, based on a previously publishedEGS4Monte Carlo code, updates the classic data set of Berger and provides more extensive calculations than previously available. Air kerma strength per unit photon emission rate from an isotropic point emitter is obtained as a function of energy using published data for mass energy absorption coefficients. The TG‐43 dose rate constant for water as a function of energy is calculated for monoenergetic photon emitters as the ratio of dose rate to water at 1 cm to air kerma strength for unit photon emission rate. Results for the radial dose distribution agree well with the data of Berger between 40 and 400 keV. For energies ⩾500 keV, a previously undescribed buildup region for the radial dose function is identified. Thickness of the buildup region ranges from 1 mm at 500 keV to 8 mm at 2 MeV. Between 15 and 30 keV, the radial dose function within a few millimeters of the emitter is calculated to be 4%–5% higher than values derived from Berger's data. The maximum dose rate constant for monoenergetic photon emitters occurs at an energy of 60 keV, and has the value 1.355 cGy h−1U−1, where U is the unit of air kerma strength, 1 μGy m2h−1. This would correspond to the maximum hypothetical dose rate constant for a brachytherapy photon source emitting photons of energy ⩽2 MeV.Keywords
This publication has 13 references indexed in Scilit:
- Photon mass attenuation and energy-absorption coefficientsPublished by Elsevier ,2002
- Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43Medical Physics, 1995
- Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study [Med. Phys. 21 , 631-641 (1994)]Medical Physics, 1994
- Comparison of radiation dosimetry in water and in solid phantom materials for I‐125 and Pd‐103 brachytherapy sources: EGS4 Monte Carlo studyMedical Physics, 1994
- Installation of EGS4 Monte Carlo code on an 80386-based microcomputerMedical Physics, 1992
- A comparison of radial dose functions for 103Pd, 125I, 145Sm, 241Am, 169Yb, 192Ir, and 137Cs brachytherapy sourcesInternational Journal of Radiation Oncology*Biology*Physics, 1992
- Comparison of measured and calculated dose rates in water near I‐125 and Ir‐192 seedsMedical Physics, 1991
- Monte Carlo techniques in medical radiation physicsPhysics in Medicine & Biology, 1991
- Monte Carlo evaluation of specific dose constants in water for 1 2 5 I seedsMedical Physics, 1988
- Structure and Operation of the EGS4 Code SystemPublished by Springer Nature ,1988