Echocardiographic Assessment of Global Ventricular Function Using the Myocardial Performance Index in Rats with Hypertrophy
- 6 April 2004
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 28 (4) , 332-337
- https://doi.org/10.1111/j.1525-1594.2004.47350.x
Abstract
Myocardial hypertrophy is the hallmark of chronic pressure overload and the myocardial performance index (MPI) is an easily recordable measurement of Doppler time intervals. In this study, the utility of using MPI to assess the progression of hypertrophy in the aortic-banded rat model was evaluated. Male Wistar rats (70-90 g) underwent ascending aorta constriction (n = 4) or a sham operation (n = 5). High-resolution echocardiography was performed 4, 7, 10, and 12 weeks after the surgery. Over this follow-up interval, animals in the aortic-banded group demonstrated an increase in their mean left ventricular (LV) mass and MPI compared with controls. MPI reflects ventricular performance in small animals with LV hypertrophy, showing alterations early after aorta constriction.Keywords
This publication has 27 references indexed in Scilit:
- Long-term left ventricular echocardiographic follow-up of SHR and WKY rats: effects of hypertension and ageAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Correlation of the tei index with invasive measurements of ventricular function in a porcine modelJournal of the American Society of Echocardiography, 2003
- Prognostic importance of systolic and diastolic function after acute myocardial infarctionAmerican Heart Journal, 2003
- Noninvasive Doppler-derived myocardial performance index: Correlation with simultaneous measurements of cardiac catheterization measurementsJournal of the American Society of Echocardiography, 1997
- Doppler index combining systolic and diastolic myocardial performance: Clinical value in cardiac amyloidisisJournal of the American College of Cardiology, 1996
- Doppler Index Combining Systolic and Diastolic Myocardial Performance: Clinical Value in Cardiac AmyloidosisJournal of the American College of Cardiology, 1996
- Alteration of growth responses in established cardiac pressure overload hypertrophy in rats with aortic banding.Journal of Clinical Investigation, 1995
- Remodelling of left ventricle after banding of ascending aorta in the ratCardiovascular Research, 1990
- Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.Circulation, 1978