Results of the Predictors of Response to CRT (PROSPECT) Trial
Top Cited Papers
- 20 May 2008
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 117 (20) , 2608-2616
- https://doi.org/10.1161/circulationaha.107.743120
Abstract
Background— Data from single-center studies suggest that echocardiographic parameters of mechanical dyssynchrony may improve patient selection for cardiac resynchronization therapy (CRT). In a prospective, multicenter setting, the Predictors of Response to CRT (PROSPECT) study tested the performance of these parameters to predict CRT response. Methods and Results— Fifty-three centers in Europe, Hong Kong, and the United States enrolled 498 patients with standard CRT indications (New York Heart Association class III or IV heart failure, left ventricular ejection fraction ≤35%, QRS ≥130 ms, stable medical regimen). Twelve echocardiographic parameters of dyssynchrony, based on both conventional and tissue Doppler–based methods, were evaluated after site training in acquisition methods and blinded core laboratory analysis. Indicators of positive CRT response were improved clinical composite score and ≥15% reduction in left ventricular end-systolic volume at 6 months. Clinical composite score was improved in 69% of 426 patients, whereas left ventricular end-systolic volume decreased ≥15% in 56% of 286 patients with paired data. The ability of the 12 echocardiographic parameters to predict clinical composite score response varied widely, with sensitivity ranging from 6% to 74% and specificity ranging from 35% to 91%; for predicting left ventricular end-systolic volume response, sensitivity ranged from 9% to 77% and specificity from 31% to 93%. For all the parameters, the area under the receiver-operating characteristics curve for positive clinical or volume response to CRT was ≤0.62. There was large variability in the analysis of the dyssynchrony parameters. Conclusion— Given the modest sensitivity and specificity in this multicenter setting despite training and central analysis, no single echocardiographic measure of dyssynchrony may be recommended to improve patient selection for CRT beyond current guidelines. Efforts aimed at reducing variability arising from technical and interpretative factors may improve the predictive power of these echocardiographic parameters in a broad clinical setting.Keywords
This publication has 29 references indexed in Scilit:
- Executive Summary: HFSA 2006 Comprehensive Heart Failure Practice GuidelineJournal of Cardiac Failure, 2006
- The Polymorphonuclear Leukocyte and the Abdominal Aortic AneurysmCirculation, 2005
- Guidelines for the diagnosis and treatment of chronic heart failure: executive summary (update 2005)European Heart Journal, 2005
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureNew England Journal of Medicine, 2005
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureNew England Journal of Medicine, 2004
- Combined Cardiac Resynchronization and Implantable Cardioversion Defibrillation in Advanced Chronic Heart FailureJAMA, 2003
- Cardiac resynchronization therapy tailored by echocardiographic evaluation of ventricular asynchronyJournal of the American College of Cardiology, 2002
- Cardiac Resynchronization in Chronic Heart FailureNew England Journal of Medicine, 2002
- Proposal for a new clinical end point to evaluate the efficacy of drugs and devices in the treatment of chronic heart failureJournal of Cardiac Failure, 2001
- Left ventricular versus biventricular dysfunction in idiopathic dilated cardiomyopathyThe American Journal of Cardiology, 1999