EGS4 Monte Carlo determination of the beta dose kernel in water
- 1 March 1990
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 17 (2) , 179-186
- https://doi.org/10.1118/1.596565
Abstract
The EGS4 Monte Carlo code has been used to simulate the emission and energy deposition in H2O about point sources of monoenergetic electrons and radionuclides of potential use in radioimmunotherapy. The radiations studied were 0.05, 0.1, 0.5, 1.0, 2.0, and 3.0 MeV monoenergetic electrons and 32P, 67Cu, 90Y, 105Rh, 131I, 153Sm, 186Re and 188Re.beta. particles and conversion and Auger electrons. Ten batches of 10,000 electrons (or 10,000 radionuclide decays) each were started isotropically at a point in an infinite homogeneous H2O phantom. The parameter-reduced electron-step transport algorithm (PRESTA) version of the EGS4 Monte Carlo code was used to follow these and their progeny, scoring the energy deposited in thin spherical shells. The scaled dose kernels are calculated and compared to kernels available in the literature. These previously published kernels either completely ignore secondary electrons or are based on a Monte Carlo code which improperly sampled the Landau energy straggling distribution.Funding Information
- National Cancer Institute (CA48902-01)
This publication has 3 references indexed in Scilit:
- BETA-DOSE POINT KERNELS FOR RADIONUCLIDES OF POTENTIAL USE IN RADIOIMMUNOTHERAPY1989
- Differences in electron depth‐dose curves calculated with EGS and ETRAN and improved energy‐range relationshipsMedical Physics, 1986