CERR: A computational environment for radiotherapy research
Top Cited Papers
- 24 April 2003
- journal article
- Published by Wiley in Medical Physics
- Vol. 30 (5) , 979-985
- https://doi.org/10.1118/1.1568978
Abstract
A software environment is described, called the computational environment for radiotherapy research (CERR, pronounced "sir"). CERR partially addresses four broad needs in treatment planning research: (a) it provides a convenient and powerful software environment to develop and prototype treatment planning concepts, (b) it serves as a software integration environment to combine treatment planning software written in multiple languages (MATLAB, FORTRAN, C/C++, JAVA, etc.), together with treatment plan information (computed tomography scans, outlined structures, dose distributions, digital films, etc.), (c) it provides the ability to extract treatment plans from disparate planning systems using the widely available AAPM/RTOG archiving mechanism, and (d) it provides a convenient and powerful tool for sharing and reproducing treatment planning research results. The functional components currently being distributed, including source code, include: (1) an import program which converts the widely available AAPM/RTOG treatment planning format into a MATLAB cell-array data object, facilitating manipulation; (2) viewers which display axial, coronal, and sagittal computed tomography images, structure contours, digital films, and isodose lines or dose colorwash, (3) a suite of contouring tools to edit and/or create anatomical structures, (4) dose-volume and dose-surface histogram calculation and display tools, and (5) various predefined commands. CERR allows the user to retrieve any AAPM/RTOG key word information about the treatment plan archive. The code is relatively self-describing, because it relies on MATLAB structure field name definitions based on the AAPM/RTOG standard. New structure field names can be added dynamically or permanently. New components of arbitrary data type can be stored and accessed without disturbing system operation. CERR has been applied to aid research in dose-volume-outcome modeling, Monte Carlo dose calculation, and treatment planning optimization. In summary, CERR provides a powerful, convenient, and common framework which allows researchers to use common patient data sets, and compare and share research results.Keywords
Funding Information
- Computerized Medical Systems, Inc. (R29 CA85181)
This publication has 7 references indexed in Scilit:
- A DICOM-RT-based toolbox for the evaluation and verification of radiotherapy plansPhysics in Medicine & Biology, 2002
- Irradiated esophageal surface area predicts for esophagitis in patients treated for non-small cell carcinoma of the lungInternational Journal of Radiation Oncology*Biology*Physics, 2002
- Recovery kinetics of salivary function in patients with head and neck cancers receiving radiation therapyInternational Journal of Radiation Oncology*Biology*Physics, 2002
- Treatment plan review tools incorporating spatial dose-volume informationInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Extending Python with FortranComputing in Science & Engineering, 1999
- Integrated software tools for the evaluation of radiotherapy treatment plansInternational Journal of Radiation Oncology*Biology*Physics, 1994
- Portable software tools for 3d radiation therapy planningInternational Journal of Radiation Oncology*Biology*Physics, 1994