Monitoring of motor action potentials after stimulation of the spinal cord.
- 1 July 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 70 (6) , 911-918
- https://doi.org/10.2106/00004623-198870060-00016
Abstract
We recorded motor action potentials in cats, using surface electrodes placed over the soleus muscle. The action potentials were generated by stimulating the spinal cord with electrodes in the epidural space at the level of the fifth or sixth thoracic vertebra. This also was done in humans, using the same methods of stimulating and recording, but the intensity of the stimulus was adjusted to produce little or no twitch of the paraspinal muscles. In the animal experiment, the motor action potential was abolished after transection of the pyramidal tract and was progressively attenuated with effective doses of a curare-like agent. We also tested the effect of distraction, using the same technique as is used in Harrington instrumentation, and found that the amount of distraction that caused reduction of the amplitude of the motor action potential of more than 50 per cent, when sustained for longer than seven minutes, caused permanent paraplegia in two cats. The evaluation of spinal evoked potentials that were obtained from epidural electrodes placed caudad to the level of distraction, and of motor action potentials that were recorded over the soleus muscle, following the same stimulus, showed a similar pattern of reduction after distraction in five of seven cats. The other two cats had irreversible reduction of motor action potential associated with unchanged spinal evoked potential, and both cats became paraplegic.(ABSTRACT TRUNCATED AT 250 WORDS)This publication has 12 references indexed in Scilit:
- Spinal Cord MonitoringSpine, 1985
- Nerve impulse propagation along central and peripheral fast conducting motor and sensory pathways in manElectroencephalography and Clinical Neurophysiology, 1985
- Postoperative neurological deficits in segmental spinal instrumentation. A study using spinal cord monitoring.Journal of Bone and Joint Surgery, 1984
- Somatosensory cerebral potentials evoke by stimulation of the lumbo-sacral spinal cord in normal subjects and in patients with conus medullaris and cauda equina lesionsElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1984
- Evoked potentials recorded from scalp and spinous processes during spinal column surgeryElectroencephalography and Clinical Neurophysiology, 1983
- Effects of compression and ischemia on spinal cord evoked potentialsExperimental Neurology, 1983
- Sensory nerve conduction in the human spinal cord: epidural recordings made during scoliosis surgery.Journal of Neurology, Neurosurgery & Psychiatry, 1982
- The effect of spinal distraction on regional spinal cord blood flow in catsJournal of Neurosurgery, 1980
- Somatosensory evoked potentials during Harrington instrumentation for scoliosis.Journal of Bone and Joint Surgery, 1978
- Intraoperative awakening to monitor spinal cord function during Harrington instrumentation and spine fusion. Description of procedure and report of three cases.Journal of Bone and Joint Surgery, 1978