Microhardness and anisotropy of the vital osseous interface and endosseous implant supporting bone
- 1 January 1998
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 16 (1) , 54-60
- https://doi.org/10.1002/jor.1100160110
Abstract
Limited information is available on the mechanical properties of the rapidly remodeling bone that surrounds endosseous implants. Fifteen implant-bone blocks were obtained from the mid-femoral diaphyses of three mature male hounds 12 weeks after placement of the implants. To evaluate the microhardness and cortical anisotropy of bone, the implants were sectioned along their long axes. In this process, the femurs were sectioned transversely. Knoop microhardness measurements (HK) were made with a 50 g force on cortical bone and a 25 g force on periosteal callus, endocortical callus, and circumferential lamellar bone. The long diagonal of the indenter was placed parallel to the implant (in the radial bone direction). Measurements were made in cortical bone at 200, 400, 600, 800, 1,000. 1,500. 2,000. and 2,500 μm from both sides of the implant. To detect cortical anisotropy in the radial compared with the tangential direction, a second set of indentations was made perpendicular to the first. Microhardness of periosteal callus and endocortical callus and anisotropy of circumferential lamellar bone near the endocortical surfaces of the femur were also evaluated. Repeated measures analysis of variance showed significantly (p < 0.05) lower microhardness values (30.6 ± 0.8 HK [mean ± SEM]) for cortical bone at 200 μm than at any other location (range: 40.3–46.6 HK). Microhardness anisotropy was not detected in cortical bone. Furthermore, within 200 μm of the implant surface, the Knoop microhardness values were significantly lower for periosteal and endocortical calluses than for cortical bone. These data provide information about the mechanical properties of bone adjacent to endosseous implants at a microstructural level. The results are consistent with the high rate of remodeling seen adjacent to endosseous implants at 12 weeks after implantation.Keywords
This publication has 21 references indexed in Scilit:
- Mineral anisotropy in mineralized tissues is similar among species and mineral growth occurs independently of collagen orientation in rats: Results from acoustic velocity measurementsJournal of Bone and Mineral Research, 1996
- Microhardness of bone at the interface with ceramic‐coated metal implantsJournal of Biomedical Materials Research, 1995
- Stress analysis of bone modelling response to rat molar orthodonticsJournal of Biomechanics, 1995
- REMODELING DYNAMICS OF BONE SUPPORTING RIGIDLY FIXED TITANIUM IMPLANTS: A HISTOMORPHOMETRIC COMPARISON IN FOUR SPECIES INCLUDING HUMANSImplant Dentistry, 1995
- Mechanical properties of microcallus in human cancellous boneJournal of Orthopaedic Research, 1992
- Hardness, an indicator of the mechanical competence of cancellous boneJournal of Orthopaedic Research, 1989
- The evaluation of bone remodeling about orthopaedic implants with ultrasoundJournal of Orthopaedic Research, 1989
- A continuous wave technique for the measurement of the elastic properties of cortical boneJournal of Biomechanics, 1984
- Quantitative analysis on the rate of secondary bone mineralizationCalcified Tissue International, 1972
- INVESTIGATIONS ON SOME PHYSICAL PROPERTIES OF BONE TISSUECells Tissues Organs, 1958