The influence of flow and motion in MRI of diffusion using a modified CE‐FAST sequence
- 1 November 1989
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 12 (2) , 198-208
- https://doi.org/10.1002/mrm.1910120206
Abstract
Severe motion and flow artifacts are a problem in MRI of diffusion in vivo due to the application of strong magnetic field gradients. Here it is shown that image artifacts can be removed by using a modified fast-scan MRI sequence (CE-FAST) in conjunction with averaging of diffusion-weighted images. In phantom studies slow (coherent) flow (-1) in the presence of strong diffusion gradients is shown to cause signal losses in diffusion-weighted images that depend on the relative orientations of the flow direction and the diffusion gradient. On the other hand, pulsatile motions of macroscopic dimensions (e.g. 1 mm, 1 Hz, in-plane) lead to smearing and ghosting of signal intensities along the phase-encoding direction of the images. In both phantoms and rabbit brains in vivo motion artifacts were found to be reducible by averaging 8-16 images. Unfortunately. the resulting image contrast no longer represents a “true” diffusion contrast but is affected by additional signal losses due to motion averaging. All experiments were performed on a 40-cm-borc 2.35-T Bruker Medspee system. © 1989 Academic Press, Inc.This publication has 19 references indexed in Scilit:
- Rapid NMR imaging of molecular self-diffusion using a modified CE-FAST sequenceJournal of Magnetic Resonance, 1989
- MRI of “diffusion” in the human brain: New results using a modified CE‐FAST sequenceMagnetic Resonance in Medicine, 1989
- The steady-state signals in short-repetition-time sequencesJournal of Magnetic Resonance (1969), 1989
- Intravoxel incoherent motion imaging using steady‐state free precessionMagnetic Resonance in Medicine, 1988
- Motion Artifact Suppression Technique (MAST) for MR ImagingJournal of Computer Assisted Tomography, 1987
- Pseudo‐gating: Elimination of periodic motion artifacts in magnetic resonance imaging without gatingMagnetic Resonance in Medicine, 1987
- Rapid NMR imaging of dynamic processes using the FLASII techniqueMagnetic Resonance in Medicine, 1986
- The application of steady‐state free precession to the study of very slow fluid flowMagnetic Resonance in Medicine, 1986
- Self-diffusion NMR imaging using stimulated echoesJournal of Magnetic Resonance (1969), 1985
- The spatial mapping of translational diffusion coefficients by the NMR imaging techniquePhysics in Medicine & Biology, 1985