The MLC tongue-and-groove effect on IMRT dose distributions
- 14 March 2001
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 46 (4) , 1039-1060
- https://doi.org/10.1088/0031-9155/46/4/310
Abstract
We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groove effect could be up to 10% of the maximum dose in the dose distributions. For an IMRT treatment with multiple gantry angles (≥5), the difference between the dose distributions with and without the tongue-and-groove effect was hardly visible, less than 1.6% for the two typical clinical cases studied. After considering the patient setup errors, the dose distributions were smoothed with reduced and insignificant differences between plans with and without the tongue-and-groove effect. Therefore, for a multiple-field IMRT plan (≥5), the tongue-and-groove effect on the IMRT dose distributions will be generally clinically insignificant due to the smearing effect of individual fields. The tongue-and-groove effect on an IMRT plan with small number of fields (5% of maximum dose) in some cases, especially when the patient setup uncertainty is small (≤2 mm).Keywords
This publication has 22 references indexed in Scilit:
- Calculation of x-ray transmission through a multileaf collimatorMedical Physics, 2000
- Removing the effect of statistical uncertainty on dose-volume histograms from Monte Carlo dose calculationsPhysics in Medicine & Biology, 2000
- The effect of dose calculation uncertainty on the evaluation of radiotherapy plansMedical Physics, 2000
- Photon beam characterization and modelling for Monte Carlo treatment planningPhysics in Medicine & Biology, 2000
- Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profilesPhysics in Medicine & Biology, 1998
- Monitor chamber backscatter for intensity modulated radiation therapy using multileaf collimatorsPhysics in Medicine & Biology, 1998
- Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimationsMedical Physics, 1994
- Characterization of a multileaf collimator systemInternational Journal of Radiation Oncology*Biology*Physics, 1993
- The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimationPhysics in Medicine & Biology, 1992
- Presta: The parameter reduced electron-step transport algorithm for electron monte carlo transportNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1986