Effects of gold nanoparticle and electrode surface properties on electrocatalytic silver deposition for electrochemical DNA hybridization detection
- 13 January 2005
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 130 (3) , 364-369
- https://doi.org/10.1039/b413143f
Abstract
In this paper we report the catalytic effects of various gold nanoparticles for silver electrodeposition on indium tin oxide (ITO)-based electrodes, and successfully apply this methodology for signal amplification of the hybridization assay. The most widely used gold nanoparticle-based hybridization indicators all promote silver electrodeposition on the bare ITO electrodes, with decreasing catalytic capability in order of 10 nm gold, DNA probe–10 nm gold conjugate, streptavidin–5 nm gold, and streptavidin–10 nm gold. Of greater importance, these electrocatalytic characteristics are affected by any surface modifications of the electrode surfaces. This is illustrated by coating the ITO with an electroconducting polymer, poly(2-aminobenzoic acid) (PABA), as well as avidin molecules, which are promising immobilization platforms for DNA biosensors. The catalytic silver electrodeposition of the gold nanoparticles on the PABA-coated ITO surfaces resembles that on the bare surfaces. With avidin covalently bound to the PABA, it is interesting to note that the changes in electrocatalytic performance vary for different types of gold nanoparticles. For the streptavidin-5 nm gold, the silver electrodeposition profile is unaffected by the presence of the avidin layer, whereas for both the 10 nm Au and DNA probe–10 nm gold conjugate, the deposition profiles are suppressed. The streptavidin–5 nm gold is employed as the hybridization indicator, with avidin-modified (via PABA) ITO electrode as the immobilization platform, to enable signal amplification by the silver electrodeposition process. Under the conditions, this detection strategy offers a signal-to-noise ratio of 20. We believe that this protocol has great potential for simple, reproducible, highly selective and sensitive DNA detection on fully integrated microdevices in clinical diagnostics and environmental monitoring applications.Keywords
This publication has 22 references indexed in Scilit:
- Electrochemical Detection of PCR Amplicons Using Electroconductive Polymer Modified Electrode and Multiple Nanoparticle LabelsElectroanalysis, 2004
- Amplified Electrical Transduction of DNA Hybridization Based on Polymeric Beads Loaded with Multiple Gold Nanoparticle TagsElectroanalysis, 2004
- Nanoparticle-based electrochemical DNA detectionAnalytica Chimica Acta, 2003
- DNA hybridization electrochemical sensor using conducting polymerBiosensors and Bioelectronics, 2003
- Directed immobilization of nucleic acids at ultramicroelectrodes using a novel electro-deposited polymerPublished by Elsevier ,2003
- Independently-addressable micron-sized biosensor elementsBiosensors and Bioelectronics, 2003
- Electrochemical detection of DNA hybridization based on silver-enhanced gold nanoparticle labelAnalytica Chimica Acta, 2002
- Silver electrodeposition catalyzed by colloidal gold on carbon paste electrode: application to biotin–streptavidin interaction monitoringBiosensors and Bioelectronics, 2000
- Electrocatalytic Determination of Colloidal Gold Particles Using a Carbon Paste Electrode Pretreated in Cyanide MediaElectroanalysis, 2000
- Electroconducting polymers for the construction of DNA or peptide arrays on silicon chipsBiosensors and Bioelectronics, 1998