Abstract
Some activities of EURADOS Working Group 9 (WG9) are presently funded by the European Commission (CONRAD project). The objective of WG9 is to promote and co-ordinate research activities for the assessment of occupational exposures to staff at workplaces in interventional radiology (IR) and nuclear medicine. For some of these applications, the skin of the fingers is the limiting organ for individual monitoring of external radiation. Therefore, sub-group 1 of WG9 deals with the use of extremity dosemeters in medical radiation fields. The wide variety of radiation field characteristics present in a medical environment together with the difficulties in measuring a local dose that is representative for the maximum skin dose, usually with one single detector, makes it difficult to perform accurate extremity dosimetry. Sub-group 1 worked out a thorough literature review on extremity dosimetry issues in diagnostic and therapeutic nuclear medicine and positron emission tomography, interventional radiology and interventional cardiology and brachytherapy. Some studies showed that the annual dose limits could be exceeded if the required protection measures are not taken, especially in nuclear medicine. The continuous progress in new applications and techniques requires an important effort in radiation protection and training.Keywords
This publication has 25 references indexed in Scilit:
- EXTREMITY DOSIMETRY FOR RADIATION WORKERS HANDLING UNSEALED RADIONUCLIDES IN NUCLEAR MEDICINE DEPARTMENTS IN INDIAHealth Physics, 2007
- The use of extremity dosemeters in a hospital environmentRadiation Protection Dosimetry, 2006
- Feasibility study of an active extremity dosimetry prototypeRadiation Protection Dosimetry, 2005
- Radiation Exposure to the Surgeon During Fluoroscopically Assisted Percutaneous VertebroplastySpine, 2005
- A study of the distribution of dose across the hands of interventional radiologists and cardiologistsThe British Journal of Radiology, 2005
- Development of the epidermal growth factor receptor inhibitor OSI-774Seminars in Oncology, 2003
- Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern?The British Journal of Radiology, 2003
- Radiation exposure to the hands of operators during angiographic proceduresEuropean Journal of Radiology, 1995
- What Factors Influence Radiologistsʼ Finger Doses During Percutaneous Drainages Under Fluoroscopic Guidance?Health Physics, 1993
- The value of syringe shields in a nuclear medicine departmentNuclear Medicine Communications, 1985